![Facom BC2410 Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/facom/bc2410/bc2410_instruction-manual_536755019.webp)
19
2.
Connect the red positive connector ring to the positive (POS, P, +) battery terminal.
3.
Connect the negative connector ring to the negative (NEG, N, -) battery terminal.
4.
Replace and tighten the nuts to secure them.
5.
Connect the ring connector cable assembly to the charger. Take care to keep both wires and
plug away from hot and moving parts.
6.
Plug the charger power cord into an AC electrical wall outlet. Make sure to place the charger
on a dry, non-flammable surface.
7.
When the charger starts, the
GREEN LED
will be solid, and the display will show
ANALYZING BATTERY
while the charger determines that the battery is properly connected
and the condition of the battery.
8.
When the battery is fully charged, the
GREEN LED
will pulse.
9.
When charging is complete, disconnect the AC cord from the supply mains, remove
the negative connector, and finally the positive connector.
BATTERY CONNECTION INDICATOR
If the charger does not detect a properly connected battery, charging will not start and the digital
display will show one of two messages. If the display shows
CONNECT CLAMPS
, make sure
the charger is connected to the battery and the connection points are clean and making a good
connection. If the display shows
WARNING CLAMPS REVERSED
, unplug the charger from the AC
outlet, reverse the connections at the battery, and then plug the charger back in.
BATTERY CHARGING TIMES
CCA = Cold Cranking Amps Ah = Amp Hour
BATTERY SIZE/RATING
CHARGE TIME (10A)
CARS AND
TRUCKS
315-550 CCA
60-85 Ah
3½-4½ h
550-1200 CCA
85-230 Ah
5-8½ h
MARINE/DEEP-CYCLE
80 Ah
5 h
140 Ah
7½ h
160 Ah
8½ h
200 Ah
10 h
Times are based on a 50% discharged battery and may change, depending on age and condition of battery.
AUTOMATIC CHARGING MODE
When an Automatic Charge is performed, the charger switches to the Maintain Mode
automatically after the battery is charged. For a battery with a starting voltage under 1 volt, use
a manual charger to pre-charge the battery for five minutes, to get additional voltage into the
battery.
ABORTED CHARGE
If charging cannot be completed normally, charging will abort. When charging aborts, the
charger’s output is shut off, the
GREEN LED
will flash, and the display will show
CHARGE
ABORTED-BAD BATTERY
. Do not continue attempting to charge this battery. Check the
battery and replace, if necessary.
CHARGE COMPLETION AND MAINTAIN MODE
Charge completion is indicated by the pulsing
GREEN LED
and the digital display showing
FULLY CHARGED-AUTO MAINTAINING
. This indicates the charger has switched to the
Maintain Mode of operation. In this mode, the charger keeps the battery fully charged by
delivering a small current when necessary.
NOTE:
If the charger has to provide its maximum
maintain current for a continuous 12 hour period, it will go into Abort Mode (see Aborted
Charge section). This is usually caused by a drain on the battery, or the battery could be bad.
Make sure there are no loads on the battery. If there are, remove them. If there are none, have
the battery checked or replaced.
MAINTAINING A BATTERY
The BC2410 maintains 24 volt batteries, keeping them at full charge. It is not recommended for
industrial applications.