UK/IRL
UK/IRL 17
4.3 Fitting the firebox (continuing)
3. The surface of the floor must be sufficiently flat to enable the bottom of the front
surround and door to be aligned horizontally.
4. The front face of the fireplace should be reasonably flat over the area covered by
the firebox to ensure good sealing.
5. Make the gas connection according to the instructions (also see gas connection,
chapter 4.1).
6. Secure the vent connector unit to the flue pipe or chimney liner.
The flue connector outer collar is for connection to a 125 mm (5 inch)
internal diameter pipe or liner. The inner collar is for connection to a
100 mm internal pipe or liner (see fig.)
UK/IRL
UK/IRL 18
4.3 Fitting the firebox (continuing)
7. Slide the clamping plate with the lip upward under the vent connector. The flue
connector and pipe or liner rests on the clamping plate. Make sure that the lip of
the clamping plate goes in the slot on the front of the firebox (see fig.).
8. Slide the burner chamber into the firebox.
9. Pull the clamping plate out. The flue collar plate makes contact with the burner
chamber.