UK/IRL
UK/IRL 31
8.1.5 Gas control block
A. Governor
B. Adjusting screw pilot flame
C. Working pressure
8.1.6 Combustion test
A BS7967 combustion analysis check should be carried out using an analyser to
BS7927 positioned in the flue outlet, or draft diverter, or spillage test opening .
A Ratio of CO/CO2 should be less than 0.01 within 30 minutes (100 ppm CO per 1%
CO2).
A reading of CO in the room centre should give a rise of less than 9 ppm over
ambient, peak reading.
UK/IRL
UK/IRL 32
LIST OF SPARE PARTS
Timra
Vista
Description
Company Part
Company Part
1
Trim
208399xx
208400xx
Glass frame
208403xx
208403XX
2
Glass
04510200
04510200
2.2
Glass ash tray
04510100
04510100
3
Burner NG
20900187
20900187
Burner LPG
20900188
20900188
4
Log set
20793300
20793300
5
HT lead
06017301
06017301
6
Receiver
20604405
20604405
7
Remote control
20603900
20603900
8
Transformer
20900142
20900142
9
Gas control NG
37003089
37003089
Gas control LPG
37003094
37003094
10
Motor Remote control
37003086
37003086
11
Pilot assembly NG
20900145
20900145
Pilot assembly LPG
20900154
20900154
12
Thermo couple
37002033
37002033
13
electrode
06006600
06006600
14
Interrupter
37006027
37006027
15
Embers
20777300
20777300
16
spray for combustion chamber
09000008
09000008
17
spring ash pan cover door
27132300
27132300
18
TTB
37006055
37006055
19
TTB-lead front
06021900
06021900
20
TTB-lead back
06021800
06021800
Содержание TIMRA
Страница 2: ......