background image

 

 

Duet XL    

 

40010749/0

929 

 

 

 

 

Installation guide 

 

ENG 

ENG 

 

Содержание Duet XL

Страница 1: ...Duet XL 40010749 0929 Installation guide ENG ENG ...

Страница 2: ...L 1 1 1 1 2 1 3 1 4 1 5 1 6 1 7 A ...

Страница 3: ...L 2 2 1 2 2 2 3 2 4 B A ...

Страница 4: ...L 3 2 5 2 6 2 7 2 8 ...

Страница 5: ...L 4 3 1 3 2 3 3 F F ...

Страница 6: ... without optional decorative sheet 11 4 9 Frameless with optional decorative sheet 11 5 removing the glass 11 5 1 removing the glass in front 11 5 2 removing the glass on the side 11 6 Plaatsen van het decoratiemateriaal 12 6 1 Imitation logs 12 6 2 Pebbles 12 7 Checking the installation 13 7 1 Checking the ignition of the pilot burner main burner 13 7 2 Checking for gas leakage 13 7 3 Checking th...

Страница 7: ...4 Dimentions of the appliance left hand side 20 15 Dimensions of the appliance left hand side with decoration plate 21 16 Dimentions of the appliance right hand side 22 17 Dimensions of the appliance right hand side with decoration plate 23 18 Dimentions ventilatie grills 24 19 Dimention service Hatch 25 ...

Страница 8: ...or ambience and heating purposes This means that all surfaces of the appliance including the glass can become very hot hotter than 100 C An exception to this are the bottom of the appliance and the controls Do not place any inflammable materials within a of 0 5 m of the radiation of the appliance and ventilation grills Due to natural air circulation of the appliance moisture and volatile component...

Страница 9: ...the finish use special stucco min 100 C resistant or glass fibre wallpaper to prevent discoloration or cracks etc Recommended drying time for plaster is a minimum of 24 hours per mm of coat applied The false chimney breast and its construction may not rest on the appliance 3 3 Requirements flue system and outlets You should always make use of the materials prescribed by Faber International Ltd Onl...

Страница 10: ...ust be of adequate size with near the appliance a gas isolater tap that should always be accessible Place the gas connection in such a way that this is easily accessible and that before service the burner unit can be disconnected at all times 4 2 Electric connection If an adapter is used for the power supply then a wall socket 230VAC 50Hz must be mounted in the close neighbourhood of the hearth 4 ...

Страница 11: ...uilt of other materials such as hollow bricks consult a professional expert 4 5 Mounting the smoke emission outlet materials In case of a wall or roof terminal the hole must be at least 5 mm bigger than the diameter of the flue material Horizontal parts must be installed at a 3 degree slope up away the appliance Build up the system from the appliance If this is not possible you should make use of ...

Страница 12: ...lass 4 9 Frameless with optional decorative sheet Construct the false chimney breast around against the build in frame see fig 1 1 B apart from the lower half Keep a minimum margin of 3 mm between chimney breast and the appliance in connection with the expansion of the hearth The height of the lower half should correspond with the height of the groove see fig 1 5 Place the decorative sheet on top ...

Страница 13: ...urner free from decorative material Do not toss all the decorative material onto the burner all at once as the very fine dust may block the holes in the burner 6 1 Imitation logs Spread the vermiculate preferably by hand over the tube burners in the burner slot The surface of the pebbles may be very slightly elevated from the burner plate but it should be level throughout the entire length Place t...

Страница 14: ...tector or spray 7 3 Checking the burner pressure and the pre pressure Check whether the burner pressure and the inlet pressure measured agree with the data indicated on the registration plate Measuring the inlet pressure Turn off the gas control tap Open the pressure gauge nipple B see figure 1 7 a few turns and connect a pressure gauge hose to the gas control valve Carry out this measurement when...

Страница 15: ...has been mounted The outlet o Wall terminal is installed correctly o Roof terminal is fitted and sited correctly The flue system is correctly calculated 8 Instructing the client Recommend that the appliance be serviced annually by a competent person in order to guarantee a safe use and a long lifespan Advise and instruct the client about maintenance and cleaning of the glass Emphasize the risk of ...

Страница 16: ...th a dry cloth You can use ceramic hob cleaner to clean the glass Note prevent fingerprints on the glass these will be burned into it once the appliance is used and cannot be removed anymore Carry out the check up according to the instructions in chapter 7 checking the installation 10 Conversion to a different type of gas e g propane This can only be done by installing the proper burner unit for t...

Страница 17: ... vice versa are not reckoned in the calculation The wall terminal always counts as 1 metre If there is transit under 45 then the real vertical and horizontal lengths should be calculated 11 1 Points of particular interest In case of a wall terminal the entire flue system including the wall terminal should be constructed of 200 130 flue pipes In case of a roof terminal the entire flue system should...

Страница 18: ...d D 1 x 2 m 2 m Total 4 m Count the vertical lengths Flue pipe length A 1 m Roof terminal G 1 m Total 2 m Sample calculation 2 Count the horizontal lengths Flue pipe lengths J L 0 5 0 5 1 m Bends K M 2 2 m 4 m Wall terminal 1 m Total horizontal length 6 m Count the vertical lengths Flue pipe length H 1 m Total 1m ...

Страница 19: ...placed 0 means no restrictor should be placed Generally a 30mm restrictor is pre installed Horizontaal 0 1 2 3 4 5 6 0 X X X x X X X 0 5 X X X X X X X 1 X 30 0 0 X X X 1 5 40 40 30 30 0 X X 2 45 40 40 30 0 0 0 3 50 45 40 30 30 0 0 4 60 50 45 40 30 0 0 5 65 60 50 45 30 30 0 6 70 65 60 50 45 30 30 7 70 70 65 60 50 45 x 8 70 70 70 65 60 X X 9 75 70 70 70 X X X 10 75 75 70 X X X X 11 80 80 X X X X X V...

Страница 20: ...te at 15ºC and 1013 mbar gr h 850 810 Burner pressure at full mark mbar 11 24 29 6 Injector main burner mm 2x 2 5mm 2x 1 3mm 2x 1 3mm Reduced input restraint mm 2 1 1 1 1 1 Pilot assembly SIT160 SIT160 SIT160 Code Nr 51 Nr 30 Nr 30 Diameter inlet outlet mm 200 130 200 130 200 130 Gas control valve GV60 GV60 GV60 Gas connection 3 8 3 8 3 8 Electrical connection V 220 220 220 Batteries receiver V 4x...

Страница 21: ...L 20 14 Dimentions of the appliance left hand side ...

Страница 22: ...L 21 15 Dimensions of the appliance left hand side with decoration plate ...

Страница 23: ...L 22 16 Dimentions of the appliance right hand side ...

Страница 24: ...L 23 17 Dimensions of the appliance right hand side with decoration plate ...

Страница 25: ...L 24 18 Dimentions ventilatie grills ...

Страница 26: ...L 25 19 Dimention service Hatch ...

Страница 27: ...26 L ...

Страница 28: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 ...