1)  ATTENTION! To ensure the safety of people, it is important that you read 

all the following instructions. Incorrect installation or  incorrect use of 

the product  could  cause  serious harm   to people.

  2)  Carefully read and follow the instructions before beginning to install the 

product.

  3)  Do not  leave packing materials (plastic, polystyrene, etc.)   within  

reach of  children as  such materials  are  potential  sources  of  danger.

  4)  Store these instructions for  future reference.
  5)  This product was designed and built strictly for the use indicated in this 

documentation. Any other use, not expressly indicated here, could 

compromise the good condition/operation of the product and/or be 

a source of danger.

  6)  FAAC declines all liability caused by improper use or use other than 

that for which the automated system was intended.

  7)  Do not install the equipment in an explosive atmosphere: the presence 

of  inflammable gas or fumes is a serious danger to safety.

  8)  The mechanical parts must conform to the provisions of Standards EN 

12604 and EN 12605.

    For non-EU countries, to obtain an adequate level of safety, the 

Standards mentioned above must be observed, in addition to national 

legal regulations.

  9)  FAAC is not responsible for failure to observe Good Technique in 

the construction of the closing elements to be motorised, or for any 

deformation that may occur during use.

 10)  The installation must conform to Standards EN 12453 and EN 12445.

    For non-EU countries, to obtain an adequate level of safety, the 

Standards mentioned above must be observed, in addition to national 

legal regulations.

 11)  Before attempting any job on the system, cut out electrical power .
 12)  The mains power  supply of the automated system must be fitted with 

an all-pole  switch with contact opening distance of 3mm or greater. 

Use of a 6A thermal breaker with all-pole circuit break is recommended.

 13)  Make sure that a differential switch with threshold of 0.03 A is fitted 

upstream of the system.

 14)  Make sure that the earthing system is perfectly constructed, and 

connect metal parts of  the means of  the closure to it. 

 15)  The automated system is supplied with an intrinsic anti-crushing safety 

device consisting of a torque control. Nevertheless, its tripping threshold 

must be checked as specified in the Standards indicated at point 10.

 16)  The safety devices (EN 12978 standard)  protect any danger areas 

against 

mechanical movement Risks

, such as crushing, dragging, and 

shearing.

 17)  Use of at least one indicator-light (e.g. FAACLIGHT ) is recommended 

for every system, as well as a warning sign adequately secured to the 

frame structure, in addition to the devices mentioned at point “16”.

 18)  FAAC declines all liability as concerns safety and efficient operation of 

the automated system, if system components not produced by FAAC 

are used.

19)   For maintenance, strictly use original parts by FAAC.
20)   Do not in any way modify the components of the automated system.
 21)  The installer shall supply all information concerning manual operation 

of the system in case of an emergency, and shall hand over to the 

user the warnings handbook supplied with the product.

 22)  Do not allow children, things or adults to stay near the product while 

it is operating.

 23)  Keep remote controls or other pulse generators away from children, 

to prevent the automated system from being activated involuntarily.

 24) 

Transit is permitted only when the automated system is idle.

 25)  The user must not attempt any kind of repair or direct action whatever 

and contact qualified personnel only.

 26)  Maintenance: check at least every 6 months the efficiency of the 

system, particularly the efficiency of the safety devices (including, 

where foreseen, the operator thrust force) and of the release devices.

27)  

The S800H ENC automated system automates vehicle entrances - 

pedestrians must have a separate entrance

.

28)   Power up the automated system only when expressly indicated.

 29)  Anything not expressly specified in these instructions is not permitted.

WARNINGS FOR THE INSTALLER

GENERAL SAFETY OBLIGATIONS

AUTOMATED SYSTEM S800H ENC

EC DECLARATION OF CONFORMITY

The Manufacturer

Company name:

FAAC S.p.A.

Address:

Via Calari, 10 - 40069 Zola Predosa BOLOGNA - ITALY

hereby declares that the following products:

Description:

Underground operator for swing leafs gates

Model:

S800H ENC

comply with the following applicable EU legislations: 

• EMC Directive 2004/108/EC            

• ROHS Directive 2 2011/65/UE

Furthermore, the following harmonised standards have been applied:

•  EN EN 60335-2-97:2006

•  EN ISO 12100:2010

• EN 61000-6-2:2005

• EN 61000-6-3:2007

Bologna, 22-01-2015

                                                              CEO
                                                       A. Marcellan
                                                      

Содержание S800H ENC

Страница 1: ...S800H ENC S800H ENC ...

Страница 2: ......

Страница 3: ...ng safety deviceconsistingofatorquecontrol Nevertheless itstrippingthreshold must be checked as specified in the Standards indicated at point 10 16 The safety devices EN 12978 standard protect any danger areas against mechanical movement Risks such as crushing dragging and shearing 17 Use of at least one indicator light e g FAACLIGHT is recommended for every system as well as a warning sign adequa...

Страница 4: ...or fixing cover Slots for fixing jack Support bush Flaps for recessing support box Bore for power cable or drain pipe Mechanical release lever optional Key operated release device Release and adjustment key and support bush Splined bush Cover These instructions apply to the following models S800H ENC SB SBW S800H ENC CBAC 100 180 FAAC S800H ENC is an automation in a hydraulic monobloc CLASS III fo...

Страница 5: ...during installation 5 Turn the pinion of the operator using the supplied key Fig 5 ref in the direction the gate closes until it reaches the internal stop of the piston and remove the key OPENING LIMIT SWITCH Turn the key to the mechanical stop and remove it from the pinion Fig 3 Fig 4 Fig 5 1 Bring the gate to the open position 2 Referring to the instructions in chapter 7 1 act on the operator s ...

Страница 6: ... and insert the pinion in the splined bush of the support box To facilitate the operation turn the operator until they couple 11 Position the supplied key beneath the operator as shown in figure 10 ref B to support the engine 12 Insert and screw the fixing screws with the groover as shown in figure 10 ref C to secure the operator to the support box as in figure 11 13 Open and close the gate checki...

Страница 7: ...C Inserto Immagini Pictures Collection Inserto Immagini Pictures Collection Collection de Figures Photo Kollektion Collection de Figures Photo Kollektion Inserto imágenes Fotoverzameling Inserto imágenes Fotoverzameling ...

Страница 8: ...ORT BOX CAISSON PORTANT GEHÄUSE CAJA PORTANTE BEHUIZING 270 480 A 228 B 249 B A 57 A A mm 26 47 249 DEUTSCH FRANÇAIS ITALIANO NEDERLANDS ESPAÑOL ENGLISH ITALIANO FRANÇAIS DEUTSCH Quote in mm Dimensions in mm Cotes en mm Maße in mm Cotas en mm Waarden in mm ...

Страница 9: ... utente User s guide Guida per l utente User s guide Guide pour l utilisateur Anleitungen für den Benutzer Guide pour l utilisateur Anleitungen für den Benutzer Guía para el usuario Gebruikersgids Guía para el usuario Gebruikersgids ...

Страница 10: ...oes not require instal lation of the electric lock mechanically locking the leaf when the motor is not running The model without hydraulic lock always requires one or more electric locks to guarantee mechanical locking of the leaf S800H ENC automations are designed and built to automate swing gates They must not be used in any other way Regarding the chosen model the system can automate leaves up ...

Страница 11: ...an optional manual emergency hydraulic release Fig 2 You must act on the key operated release device when needing to move the gate by hand without accessing the foundation box The device is installed at the base of the gate and allows you to release the system Proceed as follows to move the leaf by hand 1 To release insert the key in the lock and turn it anticlockwise to the mechanical stop 4 Move...

Страница 12: ...5 S800H ENC 532096 Rev B www faacgroup com ...

Страница 13: ...THE OPERATOR Fig 7 POUR GARANTIR UNE INSTALLATION CORRECTE IL FAUT QUE L AXE DE ROTATION DU VANTAIL SOIT PARFAITEMENT ALIGNÉ AVEC L OPÉRATEUR Fig 7 ZUR GEWÄHRLEISTUNG EINER SACHGEMÄSSEN MONTAGE MUSS DIE DREHACHSE DES TORFLÜGELS PERFEKT ZUM ANTRIEB GEFLUCHTET SEIN Abb 7 PARA GARANTIZAR UNA CORRECTA INSTALACIÓN EL EJE DE ROTACIÓN DE LA HOJA DEBE ESTAR ALINEADO PERFECTAMENTE RESPECTO AL OPERADOR Fig ...

Страница 14: ... DEUTSCH FRANÇAIS ITALIANO NEDERLANDS ESPAÑOL ENGLISH ITALIANO FRANÇAIS DEUTSCH ...

Страница 15: ...key to the mechanical stop and remove it from the pinion Insert the key without moving the pinion and check that it is at the following position 5 Turn the pinion of the operator using the supplied key Fig 14 ref in the direction the gate closes until it reaches the internal stop of the piston and remove the key 6 Without moving the pinion insert the supplied key on the operator Check the position...

Страница 16: ... the gate remains at the closed position as in figure 20 ref 12 Lift the operator using the specific panels Fig 21 ref A and insert the pinion in the splined bush of the support box To facilitate the operation turn the operator until they couple 13 Place the supplied key beneath the operator Fig 21 ref B to support the engine 14 Insert and screw the fixing screws with the groover Fig 21 ref C to s...

Страница 17: ...d have a cross section of 2 5 mm and be no longer than 20 m The overall extension of the BUS line cables must not exceed 100 m all the accessory BUS connection cables included 1 Connect the engine Fig 1 ref and the encoder Fig 1 ref to the electronic equipment according to the instructions 2 Secure the cover of the support box with the supplied screws Fig 24 25 3 Where foreseen by standards in for...

Страница 18: ...mation to malfunction This can be seen when the leaf moves abnormally and makes too much noise while operating Proceed as follows to solve the problem 1 Command the gate to open 2 While the leaf is moving loosen the opening bleed screw Fig 29 ref 3 Allow air to exit the hydraulic circuit through the bleed screw until non emulsified oil seeps out 4 Tighten the bleed screw before the operator finish...

Страница 19: ......

Страница 20: ... 49 30 5679 6645 faactm info faacgroup com www faac de INDIA FAAC INDIA PVT LTD Noida Delhi India tel 91 120 3934100 4199 www faacindia com IRELAND NATIONAL AUTOMATION LIMITED Boyle Co Roscommon Ireland tel 353 071 9663893 www faac ie MIDDLE EAST FAAC MIDDLE EAST FZE Dubai Silicon Oasis free zone tel 971 4 372 4187 www faac ae NORDIC REGIONS FAAC NORDIC AB Perstorp Sweden tel 46 435 779500 www faa...