Photo Eye, Safety Edge, Safety Loop:
Normally Closed (NC) of safety device
= #5 ter minal on gate opener control board.
Common (COM) or Ground (GND) of safety device
= #14 ter minal on gate opener control
board.
12V Power positive (+) or (12V) or (PWR) of safety device
= #11 ter minal on gate opener
control board.
12V Power Negative (
-
) or (GND) or (PWR) of safety device
= #12 ter minal on gate opener
control board.
*Remove safety jumper from #5 terminal if using a safety device.
Solenoid Gate Lock:
Terminal 1 of lock control board
= #7 ter minal on gate opener cir cuit board
Terminal 2 of lock control board
= Negative battery lead of gate opener battery
Terminal 3 of lock control board
= Negative (black) lead of gate lock
Terminal 4 of lock control board
= Positive lead of gate lock
Terminal 5 of lock control board
= Positive battery lead of gate opener battery
Magnetic Gate Lock: Magnetic gate locks must have their own power supply and their own
relay.
Coil of relay for magnetic lock
= #7 ter minal on gate opener control board.
Coil of relay for magnetic lock
= #12 ter minal on gate opener control board.
Connect positive lead of the power supply directly to the positive lead of the mag lock.
Connect negative lead of the power supply to the N/C terminal of the relay.
Connect the COM terminal of the relay to the negative lead of the mag lock.