manualshive.com logo in svg
background image

7.4  TIME LEARNING - SET-UP

 

Before any moviment is executed, the Encoders 
must be wired as explained on chapter 8.1 
page 6.

 Before any manoeuvre is executed, a SETUP 

cycle must first be run.

 During SETUP do not interrupt the photocells 

because their interruption causes the immediate 
stop of the leaves. To end the procedure, 
repeat SETUP from the beginning.

When the board is powered up and a SET-UP cycle has never 
been executed, LEDs LD4 and LD5 begin to flash slowly to signal 
that a SET-UP cycle must be executed.
There are two possible types of SETUP: AUTOMATIC and 
MANUAL

7.4.1 AUTOMATIC 

SET-UP

To execute an AUTOMATIC SET-UP, follow the procedure below:

Take the leaves to mid-opening (very important).

Hold down the SET-UP (SW1) push-button until the 2 adjacent 
LEDs (LD4 and LD5) light up on steady beam.
Release the SETUP push-button, LEDs LD4 and LD5 begin 
to flash rapidly.
Leaf 2 (if present) starts the closing movement, stopping 
when it reaches the closing mechanical stop.
Leaf 1 starts the closing movement, stopping when it 
reaches the closing mechanical stop.
Leaf 2 (if present) starts the opening movement after the 
Leaf 1 stops opening.
Leaf 2 (if present) stops when it reaches the opening 
mechanical stop.
Wait for LEDs LD4 and LD5 to go OFF, which means that the 
SETUP procedure has finished.
Give an OPEN pulse to close the gate.

 When the SET-UP procedure has been started, 

if the leaves at point 4 and 5 open instead of 
closing, the motor power supply cables must 
be changed over.

 When using the AUTOMATIC SET-UP, the slow 

down spaces, the leaf opening and closing 
delays, and the pause time (30 sec., with A 
logic), are all preset by the board and cannot 
be modified.

1.

2.

3.

4.

5.

6.

7.

8.

9.

LED

ON (closed contact)

OFF (open contact)

STOP

Command disabled

Command enabled

OPEN A

Command enabled

Command disabled

OPEN B

Command enabled

Command disabled

BUS

See par. 8.3

 7.  START-UP

7.1  LEDS CHECK

The following table shows the status of the LEDs in relation to 
the status of the inputs (the closed at rest automated system 
condition is shown in bold).
Check the status of the signalling LEDs as per table below:

Tab.1 – Operation of inputs status LEDs

 If you connect an electric lock to terminal J4, 

position DS4 to ON to enable the reversing stroke 
(before opening, the motors thrust to close, thus 
facilitating the electric lock to uncouple).

  If you set dip-switch DS3 to ON, a special function 

is enabled, allowing the gate to operate also 
in the event of wind gusts.

7.3   PRE-FLASHING

The pre-flashing function can be activated and disabled 
(following an OPEN command, the unit activates the flashing 
lamp for 3 seconds before it starts the movement). Procedure:

Press LOGIC key (SW3) for at least 5 secs. to ACTIVATE 
pre-flashing.
Press SPEED key (SW2) for at least 5 secs. to DESACTIVATE 
pre-flashing.

  In both cases check if the LED of the pressed key 

changes its status: in such cases it means that 
the function of the key and not the pre-flashing 
was changed.

1.

2.

7.2  DIPS-SWITCH PROGRAMMING 

The following tables show the settings of the DS1 dip-switches 
for programming encoder sensitivity, reverse thrust, and ope-
rator force.

Tab. 2 - DS1 programming (the default settings are shown in bold)

DS1

DS2

DS3

DS4

Description

ON

ON

HIGH FORCE

ON

OFF

MEDIUM - HIGH FORCE

OFF

ON

MEDIUM - LOW FORCE

OFF

OFF

LOW FORCE

ON

LOW ENCODER SENSITIVITY

OFF

HIGH ENCODER SENSITIVITY

ON

REVERSE THRUST ON

OFF

REVERSE THRUST OFF

7.4.2 MANUAL 

SET-UP

To execute a MANUAL SET-UP, follow the procedure below:

Take the leaves to mid-opening (very important)

.

Hold down the SET-UP (SW1) push-button until the leaf starts 
moving.
Release the SET-UP push-button, LEDs LD4 and LD5 begin 
to flash rapidly
Leaf 2 (if present) starts the closing movement, stopping 
when it reaches the closing mechanical stop
Leaf 1 starts the closing movement, stopping when it 
reaches the closing mechanical stop
Leaf 1 starts the closing movement, stopping when it 
reaches the closing mechanical stop.
Leaf 2 (if present) starts the opening movement the after 
Leaf 1 stops opening.
Leaf 2 (if present) stops when it reaches the opening 
mechanical stop.

If LOW force was set, wait for about 5 sec checking if the 
flashing lamp goes OFF.

1.

2.

3.

4.

5.

6.

7.

8.

9.

ENGLISH

5

Содержание E700

Страница 1: ...E 700 E 700...

Страница 2: ...tion This product underwent a test in a typical uniform configuration all products made by FAAC S p A Bologna 01 Mars 2008 The Managing Director A Bassi 1 BOX LAYOUT 2 2 WARNINGS 3 3 LAYOUT AND CONNEC...

Страница 3: ...lid hinges can be moved upward to allow opening the box housing Fig 3 they can also be removed and re positioned in order to enable the lid to open to the right or left When you have secured the box i...

Страница 4: ...g any work on the control unit connections maintenance always turn off power Install upstream of the system a differential thermal breaker with adequate tripping threshold Always separate power cables...

Страница 5: ...C Device with NC contact which causes contact which causes the automated the automated system to shut down system to shut down 4 OPEN B Device with N O contact see chap FUNCTION LOGICS 5 OPEN A J10 RE...

Страница 6: ...est automated system condition is shown in bold Check the status of the signalling LEDs as per table below Tab 1 Operation of inputs status LEDs If you connect an electric lock to terminal J4 position...

Страница 7: ...LEDs of both encoders show the FLASHING status In this situation refer to the configuration in TAB 3 to define which encoder connection to rotate DL 3 indicates on a steady flashing beam the reading o...

Страница 8: ...ect the main power supply transformer output and then any batteries Quickly press once only the SW1 SET UP push button to execute learning The BUS LED flashes Give an OPEN impulse leaves will move and...

Страница 9: ...e automated system performs one opening operation Make sure that the automated system is free of any obstacle created by persons or things To add other radio controls transfer the code of the memory s...

Страница 10: ...EDURE To delete ALL the input radio control codes press push button LOGIC SW3 or SPEED SW2 and while holding it down also press push button SETUP SW1 for 10 sec The LED relating to the pressed push bu...

Страница 11: ...OPEN CLOSED opens leaves opens leaf 1 no effect opening inhibited no effect opening inhibited no effect no effect opening inhibited opens leaves OPENING stops operation 1 stops operation stops operat...

Страница 12: ...rliegendem Handbuch sind unverbindlich FAAC beh lt sich das Recht vor ohne die wesentlichen Eigenschaften dieses Ger tes zu ver ndern und ohne Verbindlichkeiten in Bezug auf die Neufassung der vorlieg...

Отзывы: