1.4 Connecting Control Outputs (Digital Outputs)
COM Control Output (#1~#16, the top one is #1)
( - ) ( + )
External Power Supply (DC 12V)
Siren, Alarm, Outside Relay
Control Outputs can be automatically activated by Motion or Sensor Detections.
(To adjust these settings, please refer to the Section 3.2.4)
Only 12V (300mA) voltage and smaller is supported. When controlling devices require more voltage than
12V, use an external Outside Relay control that supports higher voltages.
Connecting Sensor Inputs
COM Sensor Input (#1~#16, the top one is #1)
Connect one signal line to the common port and connect another signal line to the desired sensor number.
(To adjust the type of sensor (NC, NO), see Section 3.1.1)
1.5 Connection with PTZ
RS-485/ 422 Adapters
RS-485/ 422 Input
□
□
□
Signal Line (+)
Ground
Signal Line (-)