XTP II CrossPoint Series • SIS Configuration and Control
45
Ethernet Connection Considerations
To access the matrix switcher through the LAN connector, obtain the IP address, subnet
mask, and gateway address of the device. The default values are as follows:
•
IP address = 192.168.254.254
•
Subnet mask = 255.255.0.0
•
Gateway address = 0.0.0.0
The Ethernet link disconnects after a designated period of time of no activity. By default, the
timeout period is 5 minutes.
NOTE:
Extron recommends leaving the default timeout at 5 minutes and periodically
issuing the Query (
Q
) command to keep the connection active. If there are long idle
periods, Extron recommends disconnecting the socket and reopening the connection
when another command must be sent.
The matrix switcher accepts up to 200 simultaneous TCP connections, including all http
sockets and telnet connections. When the matrix switcher reaches the limit, there is no
message or indication. New connections are not accepted until other connections are
closed.
Establishing a Connection
The Ethernet cable can be terminated as a straight-through cable or a crossover cable, and
must be properly terminated for your application (see
Twisted Pair Cable Termination for
on page 21).
•
Crossover cable
— Direct connection between the computer and the
XTP II CrossPoint Series matrix switcher.
•
Patch (straight-through) cable
— Connection of the XTP II CrossPoint Series matrix
switcher to an Ethernet LAN.
To connect to the XTP II CrossPoint Series matrix switcher, open a TCP socket to port 23
using the IP address of the matrix switcher.
The matrix switcher responds with a copyright message including the date, the name of the
product, firmware version, part number, and the current date and time.
•
If the matrix switcher is
not
password-protected, the device is ready to accept SIS
commands immediately after it sends the copyright message.
•
If the matrix switcher
is
password-protected, a
password
prompt appears below the
copyright message. Enter the appropriate administrator or user password.
NOTES:
•
If the password is accepted, the matrix switcher responds with
Login User
or
Login Administrator
. If the password is not accepted, the
Password
prompt
reappears.
•
For the XTP II CrossPoint 6400 only
: the factory set administrator password
is the product serial number. Enter the serial number in the
password
prompt
for initial setup. After initial setup, you may reset the password (see the
administrator password command
on page 64, or
on
page 73).