XTP II CrossPoint Series • Installation
12
A
— Install input boards or blank plates in the available slots in any
order or arrangement. Note the input numbers associated with each slot. The boards
align vertically except on the XTP II CrossPoint 1600 where they align horizontally.
Ensure a board or blank plate is installed in every slot.
B
— Install output boards or blank plates in the available slots in any
order or arrangement. Note the output numbers associated with each slot. The boards
align vertically except on the XTP II CrossPoint 1600 where they align horizontally.
Ensure a board or blank plate is installed in every slot.
C
Remote RS-232 and RS-422 connector
— Connect a host device to the 9-pin D
connector for serial RS-232 or RS-422 control of the matrix switcher (see
on page 19 for wiring details).
NOTE:
The matrix switcher supports the RS-232 or RS-422 serial communication
protocol, and operates at 9600, 19200, 38400, or 115200 baud rates.
To connect an MKP 2000 or MKP 3000 remote control panel, see to the
MKP 2000
Remote Control Panel User Guide
or the
MKP 3000 User Guide
for details.
D
— Connect a computer network to the RJ-45 connector to
control the matrix switcher remotely through Ethernet. Use a patch cable to connect to
a switch, hub, or router. The LAN connector includes the following LED indicators:
•
Activity LED indicator
— Blinks when the matrix switcher communicates with the
connected device.
•
Link LED indicator
— Lights when the matrix switcher is connected to an
Ethernet LAN.
E
— Press the
Reset
button to activate different reset modes
(see
F
— Connect a power supply to the AC power connector.
•
Default AC power
— Connect a 100 VAC to 240 VAC, 50-60 Hz
power source to this connector with a standard IEC power cord to
this connector.
•
Attached AC power
(XTP II CrossPoint 6400 only) —
•
North America
— Connect the power cord into a NEMA L6-20
220 VAC, 60 Hz power outlet.
•
Other regions
— Have a licensed electrician install a 200-240 VAC power
connector. Then, connect the power cord into a 200-240 VAC,
50-60 Hz power outlet. Ensure the wiring is in accordance with electrical codes.
ATTENTION:
•
The outlet or junction box must be installed near the equipment and be
easily accessible.
•
La prise de courant ou la boîte de jonction doivent être installées près
du dispositif et être facilement accessibles.
•
The installation location must provide short circuit and overcurrent
protection, to a minimum of 20 A.
•
Le lieu d’installation doit disposer d’une protection contre les courts-
circuits et la surtension de 20 A minimum.
•
Do NOT use an extension cord.
•
Ne PAS utiliser de rallonge électrique.
L6-20R
North America
X: Hot Y: Hot
G: Ground
G
X
Y