background image

 

3

Product Category

Step 1 — Cut-out Dimensions

ATTENTION:

• 

The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople. Exercise care to 
prevent scarring or damaging the furniture.

• 

L’ouverture dans la table pour le Cable Cubby doit être coupée uniquement par un ouvrier détenteur d’une licence. Veillez 
à ne pas laisser de marques ni à détériorer le mobilier.

• 

Use the appropriate metal Extron routing template or refer to the surface cutout dimensions before cutting a hole in the 
furniture or other surface. Pay special attention to the direction the unit will face. The connector access side is underlined 
(see Using a CNC wood cutter below). Extron is not responsible for miscut mounting holes.

• 

Utilisez le gabarit de détourage métallique approprié ou reportez-vous aux dimensions de découpe de la surface 
indiquées ci-après avant de découper le meuble ou la surface. Faites particulièrement attention à la direction dans 
laquelle l’unité sera dirigée. Le côté pour accéder au connecteur est souligné. Extron décline toute responsabilité en cas 
d’erreurs de coupe.

• 

Ensure that the orientation of the Cable Cubby and the hole dimensions are correct before cutting the table.

• 

Assurez vous que la position du Cable Cubby et les dimensions du trou soient correctes avant de couper la table.

• 

Ensure the table surface is at least 0.375 inch (9.5 mm) thick.

• 

Assurez vous que la surface de la table est au moins 9,5 mm (0,375 pouce) d’épaisseur.

If using a hand router, you should purchase the Extron TLP Pro 725C routing template (see “Installation Routing Templates for 
Cable Cubby Series/2 Enclosures” at 

www.extron.com

).

If using a CNC wood router, use the exact cut-out dimensions (see Using a  CNC wood cutter below).
If using a reciprocating saw or jigsaw, use the paper cut-out template (available under the Downloads tab on the TLP Pro 725C 
page at 

www.extron.com

).

Step 2 — Cut the Surface

CAUTION:

  Risk of personal injury: Wear safety glasses when operating power equipment.

ATTENTION :

  Risque de blessure: Portez des lunettes de sécurité lorsque vous utilisez l’équipement électrique.

Be certain the cut is laid out in exactly the desired location and the edge that opens on the lid is correctly oriented. After verifying 
and checking dimensions, cut a hole in the surface of the furniture where the enclosure will be installed (see “Preparing the Table” 
in the 

TLP Pro 725C Series User Guide

). There are three methods for cutting the hole in the table:

Using a hand router

Recommended method

 — Use the Extron TLP Pro 725C 

routing template (see “Installation Routing Templates for 
Cable Cubby Series/2 Enclosures” at 

www.extron.com

). 

Refer to the 

Routing Template User Guide

, available at 

www.extron.com

, to prepare the template and use the 

template to cut the hole.

NOTE:

 

The metal routing template must be 

purchased separately. It is reusable and should not 
be discarded when the installation is complete.

Using a CNC wood cutter

Recommended method

 — Use the exact cut-out 

dimensions:
8.90 +0.00/-0.02 inches W x 7.10 +0.00/-0.02 inches D
(226 +0.0/-0.1 mm W x 180 +0.00/-0.1 mm D)

NOTE:

 

The underlined dimension is the connector or 

AAP access side for the unit.

Using a reciprocating saw or jigsaw

Acceptable method

 — Use the paper cut-out template 

(available under the 

Downloads

 tab on the TLP Pro 725C 

product page at 

www.extron.com

).

USE

R AC

CES

S

EXTR

ON E

LEC

TRO

NICS

TLP 7

10C

V RO

UTE

R GU

IDE -

 ALL

 MO

DELS

STAN

DAR

D

0.625

 IN O

UTS

IDE D

IAM

ETER

 GUID

E BU

SHIN

G

0.500

 IN C

UT D

IAM

ETER

 STR

AIGH

T RO

UTE

R BIT

MET

RIC

16 M

M O

UTS

IDE D

IAM

ETER

 GUID

E BU

SHIN

G

12 M

M O

R 12

.7 M

M C

UT D

IAM

ETER

 STR

AIGH

T RO

UTE

R BIT

AND

A

Figure 3. 

Using a hand router

Cut-

Out 

Tem

pla

te fo

r th

e Ex

tron

TLP 

Pro 

720

C and 

TLP 

Pro 

725

C

1. 

Con

firm

 th

e pr

odu

ct t

o be

 ins

tal

led.

2. 

Dou

ble

-ch

eck

 th

e pr

int

 se

ttings

,

 

befo

re 

print

ing

, a

nd 

mak

e s

ure 

 

the

 pa

ge 

is 

not

 sc

ale

d.

3.  

 R

em

ove

 th

e su

rfa

ce 

cut-out

 are

a

 

(gr

ay)

 fr

om 

the

 te

mpl

ate 

by 

cut

tin

g

 

along 

the

 re

d li

ne.

 

DO

 N

OT CU

T th

e gr

ay 

dot

ted 

line

s.

4. 

Mea

sure 

the

 cu

tou

t a

nd te

mpl

ate

 

Mak

e sure

 th

e di

mens

ion

s a

re th

e

 

sam

e a

s thos

e sh

own

.

5. 

Pla

ce 

the

 te

mpl

ate

 and 

mar

k th

 

pos

ition

 on 

the

 m

oun

ting

 su

rfa

ce 

 

whe

re 

the

 R

WM

 2 

is 

bein

g  in

sta

lle

d.

6.  

 D

oub

le 

che

ck 

pos

itio

n an

d

 

dim

ens

ion

s, t

hen 

cut

 th

e o

peni

ng

 

in th

e wa

ll.

68-21

79-

02 R

ev.

 B

Trim

 Ri

ng 

Oute

r E

dge

(Do 

not

 cu

t th

is lin

e.)

Page

 si

ze:

 11" 

x 17

"

Prin

t sc

ale

 1:1

Do n

ot s

hrink

.

User

 Acces

s

User

 A

cce

ss

R =

 0.

25"

 (6

.4 

mm

)

7.1

0"

(18

0 m

m)

8.9

0"

(22

6 m

m)

+ 0

.00

" (0

.00

 cm

)

- 0

.02

" (0

.05 

cm

)

SU

RFA

CE 

CUT

-OU

T

ARE

A

Trim

 R

ing 

Lip

Widt

h =

 0.

325

" (8

.3 

mm

)

 

Trim

 R

ing 

O

Trim

r E

dge

r E

dg

er E

d

ter E

d

ute

rE

(Do 

not

 cu

t

(Do

his

 line

.

his

l

his

li

this

li

this

l

 th

is

)

Figure 4. 

Using a reciprocating saw or jigsaw

Содержание TouchLink TLP Pro 725C Series

Страница 1: ...el Toolbelt Provides device discovery device information firmware updates and configuration of network settings system utilities and user management for TouchLink Pro devices Global Scripter Provides an integrated development environment for Extron control systems programming NOTE All four software programs are available from www extron com Obtain the following network information from your networ...

Страница 2: ...tor to the LAN and power it on see figure 9 Set up the Touchpanels for Network Communication Connect the PC that you are using for setup the control processor and the touchpanel to the same Ethernet subnetwork Use the Setup Menu see page 8 or Toolbelt to set the DHCP status and if necessary the IP address subnet mask gateway and related settings for the touchpanel Configure the Touchpanels The GUI...

Страница 3: ...C Series User Guide There are three methods for cutting the hole in the table Using a hand router Recommended method Use the Extron TLP Pro 725C routing template see Installation Routing Templates for Cable Cubby Series 2 Enclosures at www extron com Refer to the Routing Template User Guide available at www extron com to prepare the template and use the template to cut the hole NOTE The metal rout...

Страница 4: ...Guide and Retractors User Guide at www extron com Step 5 Assemble Pass through Cable Module Optional 1 Pass the cables through the connectivity module from the bottom see figure 5 1 2 Insert the cable into the grommet plate 2 3 Fill any unused holes with the provided plugs 3 4 Attach the grommet plate to the top of the connectivity module using four of the provided 4 40 thread forming screws 4 To ...

Страница 5: ...on secteur autre que le modèle Cable Cubby AC Power Module To install the power cable pass through or AAP modules follow these instructions 1 Insert the module into the cable cubby figure 7 1 Make sure the mounting holes on the module line up with the holes on the Cable Cubby enclosure If you are installing retractors they should be secured using the lowest level of mounting holes inside the touch...

Страница 6: ...d and ensure that the lever is down Slide the clamp all the way up against the bottom of the table Ensure the TLP Pro 725C is firmly seated in the table Rotate the lever up to secure the enclosure 2 1 3 Lever Figure 8 Mounting the TLP Pro 725C Enclosure Locking Plate NOTE To lower the side clamp turn the lever down then press and hold the locking plate while sliding down the clamp 2 Rotate the sid...

Страница 7: ...l and at least 15 from the center axis When no motion has been detected for a user defined period of time the touchpanel enters sleep mode When motion is detected by the sensor the screen display is restored and active C Communication LED This LED shows the configuration and connection status of the touchpanel Unlit during normal operation the touchpanel is configured and connected to an IP Link P...

Страница 8: ... to the unit Use this mode with Toolbelt software to replace firmware in the event of conflicts arising from uploading a firmware update Reset All IP Settings Press and hold the Reset button for 6 seconds After the Reset LED C flashes twice release and momentarily press the Reset button Use this mode to reset all network settings without affecting user loaded files Reset to Factory Defaults Press ...

Отзывы: