background image

 

5

Product Category

Step 7 — Install Modules

Figure 7 shows how to install a power module. The cable pass-
through module and AAP module are installed in the same way.
The TLP Pro 725C has three triple spaces available for installing 
modules. Extron recommends that, if they are installed, retractors 
should occupy one of the end spaces. There is no prefered order for 
the power module, cable pass-through module, or AAP module.
If required, power modules must be purchased separately. See the 
Extron website (

www.extron.com

) to select a power module that is 

suitable for your location.

ATTENTION:

• 

For units that are used in North America, only use AC power 
modules that are UL Listed Model “Cable Cubby AC Power 
Module”.

• 

Pour les unités qui sont utilisées en Amérique du Nord, utilisez 
seulement les modules d’alimentation secteur qui sont listés 
UL, modèle « Cable Cubby AC Power Module ».

• 

The unit is not UL Listed if it uses any AC power module other 
than Model “Cable Cubby AC Power Module”.

• 

L’unité n’est pas certifiée UL si elle utilise tout autre module 
d’alimentation secteur autre que le modèle «Cable Cubby AC 
Power Module ».

To install the power, cable pass-through, or AAP modules, follow 
these instructions.

1. 

Insert the module into the cable cubby (figure 7, 

1

). Make sure 

the mounting holes on the module line up with the holes on the 
Cable Cubby enclosure. 
If you are installing retractors, they should be secured using the 
lowest level of mounting holes inside the touchpanel enclosure. 
Cable pass-through, AAP, and power modules can be mounted at 
at any height.

2. 

Secure the modules with #6-32 Phillips head screws and star 
washers.

CAUTION:

  Risk of electric shock: To ensure proper 

electrical grounding, use the provided grounding screws 
and star washers.

ATTENTION :

  Risque de décharge électrique: Afin 

d’assurer une mise à la terre correcte, utilisez les fixations 
de mise à la terre et les rondelles en étoile fournies.

3. 

(Power module only) Run the cable or conduit to a convenient 
junction box. Extron recommends the circuit be attached to a 
junction box that is directly wired to the main circuit.

e

21-

525

-01

LF

21-

526-

01L

F

125

V~ 

12A

 MA

X T

OTA

L

Insert the modules 

into the Cable Cubby.

1

Secure the modules 

using four of the 

provided #6-32

pan-head mounting

screws and star washers.

2

Figure 7. 

Installing a Module

Содержание TouchLink TLP Pro 725C Series

Страница 1: ...el Toolbelt Provides device discovery device information firmware updates and configuration of network settings system utilities and user management for TouchLink Pro devices Global Scripter Provides an integrated development environment for Extron control systems programming NOTE All four software programs are available from www extron com Obtain the following network information from your networ...

Страница 2: ...tor to the LAN and power it on see figure 9 Set up the Touchpanels for Network Communication Connect the PC that you are using for setup the control processor and the touchpanel to the same Ethernet subnetwork Use the Setup Menu see page 8 or Toolbelt to set the DHCP status and if necessary the IP address subnet mask gateway and related settings for the touchpanel Configure the Touchpanels The GUI...

Страница 3: ...C Series User Guide There are three methods for cutting the hole in the table Using a hand router Recommended method Use the Extron TLP Pro 725C routing template see Installation Routing Templates for Cable Cubby Series 2 Enclosures at www extron com Refer to the Routing Template User Guide available at www extron com to prepare the template and use the template to cut the hole NOTE The metal rout...

Страница 4: ...Guide and Retractors User Guide at www extron com Step 5 Assemble Pass through Cable Module Optional 1 Pass the cables through the connectivity module from the bottom see figure 5 1 2 Insert the cable into the grommet plate 2 3 Fill any unused holes with the provided plugs 3 4 Attach the grommet plate to the top of the connectivity module using four of the provided 4 40 thread forming screws 4 To ...

Страница 5: ...on secteur autre que le modèle Cable Cubby AC Power Module To install the power cable pass through or AAP modules follow these instructions 1 Insert the module into the cable cubby figure 7 1 Make sure the mounting holes on the module line up with the holes on the Cable Cubby enclosure If you are installing retractors they should be secured using the lowest level of mounting holes inside the touch...

Страница 6: ...d and ensure that the lever is down Slide the clamp all the way up against the bottom of the table Ensure the TLP Pro 725C is firmly seated in the table Rotate the lever up to secure the enclosure 2 1 3 Lever Figure 8 Mounting the TLP Pro 725C Enclosure Locking Plate NOTE To lower the side clamp turn the lever down then press and hold the locking plate while sliding down the clamp 2 Rotate the sid...

Страница 7: ...l and at least 15 from the center axis When no motion has been detected for a user defined period of time the touchpanel enters sleep mode When motion is detected by the sensor the screen display is restored and active C Communication LED This LED shows the configuration and connection status of the touchpanel Unlit during normal operation the touchpanel is configured and connected to an IP Link P...

Страница 8: ... to the unit Use this mode with Toolbelt software to replace firmware in the event of conflicts arising from uploading a firmware update Reset All IP Settings Press and hold the Reset button for 6 seconds After the Reset LED C flashes twice release and momentarily press the Reset button Use this mode to reset all network settings without affecting user loaded files Reset to Factory Defaults Press ...

Отзывы: