background image

 

TLI Pro 201 • Contents

viii

Содержание TLI Pro 201

Страница 1: ...68 3514 01 Rev C 10 21 TouchLink Pro Interface Control Systems TLI Pro 201 User Guide TouchLink ...

Страница 2: ...togramme lorsqu il est utilisé sur le produit signale à l utilisateur des instructions d utilisation ou de maintenance importantes qui se trouvent dans la documentation fournie avec l équipement Pour en savoir plus sur les règles de sécurité la conformité à la réglementation la compatibilité EMI EMF l accessibilité et autres sujets connexes lisez les informations de sécurité et de conformité Extro...

Страница 3: ...marks on the Terms of Use page at www extron com Registered Trademarks Cable Cubby ControlScript CrossPoint DTP eBUS EDID Manager EDID Minder Extron eLink Flat Field FlexOS Glitch Free Global Configurator Global Scripter GlobalViewer Hideaway HyperLane IP Intercom IP Link Key Minder LinkLicense LockIt MediaLink MediaPort NAV NetPA PlenumVault PoleVault PowerCage PURE3 Quantum ShareLink Show Me Sou...

Страница 4: ...is interference must be corrected at the expense of the user NOTE For more information on safety guidelines regulatory compliances EMI EMF compatibility accessibility and related topics see the Extron Safety and Regulatory Compliance Guide on the Extron website Battery Notice This product contains a battery Do not open the unit to replace the battery If the battery needs replacing return the entir...

Страница 5: ...ponses mentioned in this guide the character 0 is used for the number zero and O represents the capital letter o Computer responses and directory paths that do not have variables are written in the font shown here C Program Files Extron Variables are written in slanted form as shown here ping xxx xxx xxx xxx t SOH R Data STX Command ETB ETX Selectable items such as menu names menu options buttons ...

Страница 6: ......

Страница 7: ... 23 Using the Software 25 TLI Pro 201 Web Page 26 Updating the Firmware 28 Downloading Firmware 28 Mounting 30 Wall Mounting 30 Rack Mounting 30 The UL Guidelines for Rack Mounting 30 Consignes UL pour le montage en rack 31 Other Mounting Options 31 Reference Material 32 Best Practices for Cleaning Your Extron Products 32 Network Port Requirements and Licensed Third Party Software 33 Reset Modes 3...

Страница 8: ...TLI Pro 201 Contents viii ...

Страница 9: ...ries control system Compatible with all IP Link Pro control processors and HC 400 Series Meeting Space Collaboration Systems HDCP 2 3 compliant HDMI Input For full motion video preview and monitoring One high speed USB 2 0 port For third party touch displays or HID support PoE compatible Product is powered directly by a PoE switch or injector eliminating the need for bulky local power supplies Ful...

Страница 10: ...POWER 12V A MAX Extron TLI Pro 201 4K TouchLink Interface RS 232 RS 232 Ethernet Ethernet Ethernet Ethernet PoE 4K 3rd Party Touchscreen USB HDMI HDMI HDMI HDMI Extron DA2 HD 4K Plus Distribution Amplifier Laptop Flat Panel Display Extron IPCP Pro 255Q xi IP Link Pro Quad Core Control Processor Science Building en n Science Building LAN MODEL 80 FLAT PANEL AV LAN Figure 1 TLI Pro 201 Application D...

Страница 11: ...n this device have been set to the device serial number Passwords can be changed during configuration They are case sensitive NOTE If the device is reset to default settings the passwords are reset to the defaults which are extron for either admin or user accounts MAC address Make a note of the interface MAC address see the label on the rear panel of the device 3 Mount the TLI Pro 201 in a standar...

Страница 12: ...lt Help File to set the DHCP status and if necessary the IP address subnet mask gateway and related settings for the interface 7 Configure the interface The Global Configurator Professional and Global Configurator Plus Help File and the GUI Designer Help File provide step by step instructions and detailed information The Global Configurator Professional and Global Configurator Plus Help File inclu...

Страница 13: ...HDMI lacing bracket to secure the HDMI connector see Securing the HDMI Connector on page 9 B HDMI Output Connect this HDMI type A port to a third party touch display Use the provided LockIt HDMI lacing bracket to secure the HDMI connector see Securing the HDMI Connector See the Output Screen Resolutions table on page 6 for a full list of video output screen resolutions supported by the TLI Pro 201...

Страница 14: ...p 60 Hz Custom 3 Defaults to 1080p 60 Hz C USB Port see figure 2 on page 5 Supports High speed USB 2 0 control Plug a USB cable from the third party touch display into this type B connector The USB connection passes information to the interface about where the touch display was pressed To use a non touch display connect a mouse to this port Use the mouse to click screen icons D LAN PoE Port The in...

Страница 15: ...mmends the Extron PI 140 power injector see figure 3 Your power injector may look different 1 Use an Ethernet cable to connect the LAN PoE port of the interface to the power output of the 802 3at class 4 compliant PoE power injector This cable carries network information from the switch or router to the power supply input 2 Connect the network input of the power injector to a network switch or rou...

Страница 16: ...conformité réglementaire Unless otherwise stated the AC DC adapters are not suitable for use in air handling spaces or in wall cavities The power supply is to be located within the same vicinity as the Extron AV processing equipment in an ordinary location Pollution Degree 2 secured to the equipment rack within the dedicated closet podium or desk Sauf mention contraire les adaptateurs AC DC ne son...

Страница 17: ...et on the screw and against the HDMI connector then tighten the screw to secure the bracket ATTENTION Do not overtighten the HDMI connection mounting screw The shield it fastens to is very thin and can easily be stripped Ne serrez pas trop la vis de montage du connecteur HDMI Le blindage auquel elle est attachée est très fin et peut facilement être dénudé 3 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 Figure 4 S...

Страница 18: ... Indicates the power status and the reset status of the unit B Reset button recessed Allows the unit to be reset in any of three different modes It also allows the user to toggle between enabling and disabling the DHCP client see Reset Modes on page 33 C Menu button recessed Opens the Setup Menu see the next page and Calibration Screen see page 21 for the interface Setup Menu 1 Press the button br...

Страница 19: ...em Volume System Mute 75 Off Device Information Model Part Number Firmware Bootloader TLI Pro 201 60 1669 01 1 00 0001 b005 1 00 0000 Output Resolution Sleep Timer 1080p 5 Input Signal 1080p at 60Hz Project Information Global Configurator Project Name GUI Project Name N A N A Network IP Address Hostname DHCP Off 192 168 254 251 TLI Pro 201 1A FF E4 Advanced Primary Controller Address System ID Sto...

Страница 20: ... Addres 00 05 A6 1A FF E4 Domain Name Figure 7 Network Screen 1 Select the Ethernet speed 100 Mbps or 1 Gbps 2 If the IP address is to be assigned by DHCP toggle the switch to On If the IP address is to be assigned manually toggle the switch to Off When DHCP is off the Host Name cannot be edited All addresses can be edited see figure 9 on page 13 When DHCP is on the Host Name can be edited The add...

Страница 21: ...r an invalid number for example 892 you are able to enter the 89 but the 2 cannot be entered When a valid three digit value is entered the next octet is automatically selected c Press SUBMIT to save the changes and return to the Network screen or press the back button to return to the Network screen without saving the changes If changes have been made to the network address the SUBMIT button chang...

Страница 22: ...t Resolution to use an imported GUI Designer project to set the resolution of the TLI Pro 201 Click Set Display to open the TLI Output Resolution and Refresh Rate dialog box see figure 11 TLI Output Resolution and Refresh Rate Refresh Rate 60 23 98 24 25 29 97 30 50 59 94 Resolution 3840x2160 1920x540 1920x720 3440x1440 3840x1080 4096x2160 C1 1080p C2 1080p C3 1080p CANCEL SAVE USE EDID SHOW ALL R...

Страница 23: ...uched When the display timer is used to deactivate the screen the screen switches off which provides better energy savings but the screen takes longer to reactivate when it is touched When the display timer expires some 3rd party touch displays cut power to the USB ports when the video sync is cut If this occurs press the MENU button on the TLI Pro 201 or disconnect and reconnect the USB cable Tes...

Страница 24: ... the resolution and refresh rate of the the connected display and the current output configuration are shown These are read only Input Status The Input Status panel is read only and shows the native resolution and refresh rate of the input device and the currently selected EDID Input Configuration The Input Configuration panel allow the input signal to be configured Aspect Ratio Allows you go togg...

Страница 25: ...ect the required refresh rate 3 Click SAVE to save this EDID or click CANCEL to close the dialog without changing the EDID You can also capture the EDID of the display connected to the TLI Pro 201 HDMI output connector see figure 2 B on page 5 1 If necessary connect a display to the OUTPUT connector 2 Open the Setup menu select INPUT and select EDID Minder 3 Click CAPTURE The Save EDID dialog open...

Страница 26: ...l faders are set to 80 In each fader control panel there is the mute button which toggles the volume between audio mute and the value set by the corresponding fader When the System volume is muted all other settings Click Sound and HDMI are also muted System volume panel can mute the output speaker the microphone line out or both System volume also sets the maximum volume for all the other sound v...

Страница 27: ...Creation Date 1920x1080_2 levels_2 sliders gdl 0 0 1 3 20 2020 3 18 28 PM Revision Date 4 21 2021 9 31 38 PM Resolution 1920x1080 Figure 18 Project Information Screen The Sytem Information Global Configurator Project and GUI Project panels are read only Advanced Touchpanel Setup EXIT STATUS NETWORK OUTPUT INPUT AUDIO PROJECT INFORMATION ADVANCED Advanced EDIT System Info Primary Controller Address...

Страница 28: ...s an existing PIN you can press EDIT The Enter New PIN dialog opens Enter New PIN 1 2 3 6 5 9 8 4 7 0 SUBMIT Figure 20 Enter New PIN dialog box 2 Enter a four digit PIN The numbers entered remain hidden see figure 20 3 Press SUBMIT When the PIN has been entered correctly the title bar changes to Confirm New Menu PIN 4 Enter the PIN a second time and press SUBMIT When the PIN entered on the second ...

Страница 29: ...1 Calibration Screen Opens 2 The calibration screen opens to show cross hairs in the top left corner see figure 21 The Top Left button in the center of the screen is highlighted 3 Touch the crosshair Once the touch is detected a box appears around the crosshair Touch center of crosshair to calibrate Top Left Top Right Bottom Right Bottom Left Figure 22 Calibration Screen Touch Detected TLI Pro 201...

Страница 30: ...en Calibrate the Next Crosshair The top left crosshair disappears The top right crosshair appears The Top Left button is replaced by a check mark The Top Right button is highlighted 4 Repeat step 3 until all four sets of cross hairs have been calibrated one in each corner 5 The touchpanel exits the Calibration screen once the calibration process is completed TLI Pro 201 On screen Menus 22 ...

Страница 31: ... user interface Alternatively the TLI Pro 201 can use Global Scripter instead of GCP to program the graphical user interface The TLI Pro 201 can use Toolbelt to configure network settings All four software products are available at www extron com see Downloading Software below Downloading Software GUI Designer Global Configurator Global Scripter and Toolbelt can be downloaded from www extron com 1...

Страница 32: ...not shown in the top panel you need to search using the alphabet menu 4 1 Click the initial letter of the product This generates a list of software products with that initial letter 2 Scroll through the list until you find the desired product 3 Click Download 4 On the next page that opens provide the information requested An executable file exe is placed in your default Downloads folder 5 Run the ...

Страница 33: ...onfigurator Plus and Global Configurator Professional Help File for step by step instructions and more detailed information The Global Configurator Plus and Global Configurator Professional Help File also includes an introduction to the software and sections on how to start and configure a project Global Scripter As an alternative to Global Configurator Plus and Professional use the Global Scripte...

Страница 34: ... your user name and password Figure 26 Login for TLI Pro 201 web page NOTES The factory configured passwords for all accounts on this device have been set to the device serial number Passwords are case sensitive If the device is reset to default settings the passwords are reset to the default password which are extron for either admin or user TLI Pro 201 Configuration Software 26 ...

Страница 35: ... and network information about the unit This information is read only Use the Setup Menu see page 11 or Toolbelt to configure the network settings of the TLI Pro 201 Figure 27 TLI Pro 201 Web Page TLI Pro 201 Configuration Software 27 ...

Страница 36: ...o 201 1 On the Extron Website click Download 1 2 Click Firmware 2 Figure 28 Firmware Download Center The Download Firmware page opens Figure 29 Selecting Firmware to Download 3 Click the letter T from the list of letters 1 4 Scroll down the page until you find the firmware for the TLI Pro 201 NOTE Your product appears in this list only if a new version of the firmware has been released since the p...

Страница 37: ... to download the program An executable file is downloaded to the PC 8 Go to the Downloads folder and click on the file to install the firmware on the PC By default it is stored at C Program Files x86 Extron Firmware product name firmware version 9 Use Toolbelt see the Toolbelt Help File to upload this file to the touchpanel TLI Pro 201 Configuration Software 29 ...

Страница 38: ...ulti unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consider installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by Extron Reduced air flow Install the equipment in the rack so that the amount of air flow required for safe operation of the equipment is not compromised Mecha...

Страница 39: ...stallez l équipement en rack de manière à éviter toute situation dangereuse causée par le déséquilibre de la charge mécanique Surcharge électrique Lorsque vous connectez l équipement au circuit d alimentation observez la connexion de l équipement et étudiez les effets possibles d une surcharge du circuit sur les protections contre les surintensités et les conducteurs d alimentation Consultez à cet...

Страница 40: ...oducts can be safely cleaned with 1 70 concentration or higher isopropyl alcohol 2 Disinfectant cleaners that Are non ammonium based for example contains no ammonium chloride Contain 2 or less sodium hypochlorite for example 2 bleach 98 water Regardless of the device it is important to follow these general guidelines when cleaning 1 If possible unplug the device 2 Spray the cleaner on a lint free ...

Страница 41: ...issues arise with user loaded firmware Activation To start the Use Factory Firmware reset mode and replace firmware 1 Remove power to the TLI Pro 201 2 On the TLI Pro 201 hold down the recessed R reset button while applying power to the unit When power is restored the Power LED lights Hold the reset button for a further 2 seconds before releasing it The TLI Pro 201 enters factory firmware mode 3 U...

Страница 42: ...tory Defaults Purpose and Notes Reset to Factory Defaults mode is useful if you want to start over with configuration and uploading Activation To reset the unit to all factory default settings 1 Hold down the reset button for about 9 seconds until the Power LED blinks three times once at 3 seconds again at 6 seconds and again at 9 seconds 2 Release and press reset momentarily for 1 second within 1...

Страница 43: ...You must run Toolbelt as an administrator Some certificates require a passphrase that is created when the certificate is created If a passphrase is required you must enter that passphrase before uploading and applying the certificate These devices support standard OpenSSL certificate encodings such as pem Privacy enhanced Electronic Mail and der Distinguished Encoding Rules file types PEM file typ...

Страница 44: ...ator Machine certificates require a private key file which can be encrypted Certificate File Requirements PEM Privacy enhanced Electronic Mail file types are ASCII encoded and they are the required format for 802 1X authentication for the TouchLink Pro control systems DER Distinguished Encoding Rules file types are binary encoded and can typically have several file extension variations such as crt...

Страница 45: ...evices It helps in monitoring of operations and factors such as packet usage memory usage remote password resets and collection of error information An information technology administrator can use common IT tools to monitor those factors as well as look up device location and the name of the contact person for the device The SNMP controls within Toolbelt provide a way to enable or disable SNMP It ...

Страница 46: ... not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or if modifications were made to the product that were not authorized by Extron NOTE If a product is defective please call Extron and ask for an Application Engineer to receive an RA Return Authorization number This will begin the repair process USA 714 491 1500 or ...

Отзывы: