background image

Application Diagram

POWER

12V         

x.xA MAX

G

Tx Rx

RTS CTS

COM 1

G

Tx Rx

G

Tx Rx

COM 2

COM 3

1

S G

S G

2

IR/SERIAL

RELAYS

1   2   C 3   4   C

1   2   3   4   G

DIGITAL I/O

PWR  OUT  =   6W

eBUS

+V +S -S G

LAN

1

2

3

IPCP PRO 350

LAN

AC

T

LINK

RESE

T

I N P U T S

O U T P U T S

1

2

3

4

5

6

7

8

US

LISTED

1T23
I.T.E.

®

1

2

3

4

5

6

7

8

TLI PRO 101

LAN/PoE

USB

HDMI

HDMI

+ -

POWER
12 V

RESET

CONTROL

OUTPUT

1.0A MAX

INPUT

Extron

TLI Pro 101

TouchLink 

Interface

STANDBY/ON

PQLS

HDMI

OPEN/CLOSE

FL OFF

USB

WiFi

1 2 3 4

!

1

@

2

#

3

$

4

%

5

^

6

&

7

*

8

(

9

)

0

_
-

+

=

|

\

}

]

{

[

~

`

Q

W

E

R

T

Y

U

I

O

P

:

;

<

,

>

.

?

/

A

S

D

F

G

H

J

Z

X

C

V

B

N

M

K

L

control

shift

caps lock

tab

esc

F1

F2

F3

F4

F5

F6 

F7

F8

F9

F10

F11

F12

F13

F14

F15

F16

F17

F18

F19

alt

option

command

delete

fn

home

clear

enter

=

/

*

8

-

5

2

7

0

.

4

1

+

9

6

3

page
up

page
down

end

delete

command

option

control

shift

return

caps lock

TCP/IP

Network

Ethernet

Ethernet

3rd Party 

Touch 

Screen

Ethernet

USB

HDMI

HDMI

RS-232

RS-232

HDMI

HDMI

HDMI

HDMI HDMI

HDMI

HDMI

HDMI

HDMI

HDMI

Monitor 1

Monitor 2

Monitor 3 

Extron

DXP 88 HDMI

HDMI Matrix Switcher

Extron

IPCP Pro 350

IP Link Pro Control 

Processor

Blu-ray Player

PC

Laptop

Document Camera

Video Camera

Figure 1. 

TLI Pro 101 Application Diagram

Requirements

Software

For a complete list of the requirements for running GUI Designer, Global Configurator Plus 
and Professional, Global Scripter, or Toolbelt, see the Extron Web page for the appropriate 
software.

NOTE:

  The TLI Pro 101 is not compatible with Global Configurator 3 or GUI Configurator.

Hardware

An Extron IP Link Pro control processor must be connected to the same network domain as 
the TLI Pro 101. See 

www.extron.com

 for a list of suitable controllers.

NOTE:

  The TLI Pro 101 is not compatible with Extron IP Link (non-Pro) control 

processors.

 

TLI Pro 101 • Introduction

2

Содержание TLI Pro 101

Страница 1: ...68 1817 01 Rev E 04 20 TouchLink Pro Interface Control Systems TLI Pro 101 User Guide TouchLink ...

Страница 2: ...se trouvent dans la documentation fournie avec le matériel Pour en savoir plus sur les règles de sécurité la conformité à la réglementation la compatibilité EMI EMF l accessibilité et autres sujets connexes lisez les informations de sécurité et de conformité Extron réf 68 290 01 sur le site Extron www extron com Istruzioni di sicurezza Italiano AVVERTENZA Il simbolo se usato sul prodotto serve ad ...

Страница 3: ... この記号 が製品上に表示されている場合は 本機の取扱説明書に 記載されている重要な操作と保守 整備 の指示についてユーザーの注意 を喚起するものです 安全上のご注意 法規厳守 EMI EMF適合性 その他の関連項目に ついては エクス トロンのウェブサイ ト www extron com より Extron Safety and Regulatory Compliance Guide P N 68 290 01 をご覧ください 안전 지침 한국어 경고 이 기호 가 제품에 사용될 경우 제품의 인클로저 내에 있는 접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을 경고합니다 주의 이 기호 가 제품에 사용될 경우 장비와 함께 제공된 책자에 나와 있는 주요 운영 및 유지보수 정비 지침을 경고합니다 안전 가이드라인 규제 준수 EMI EMF 호환성 ...

Страница 4: ...right 2014 2020 Extron Electronics All rights reserved Trademarks All trademarks mentioned in this guide are the properties of their respective owners The following registered trademarks registered service marks SM and trademarks TM are the property of RGB Systems Inc or Extron Electronics see the current list of trademarks on the Terms of Use page at www extron com Registered Trademarks Cable Cub...

Страница 5: ...ponses mentioned in this guide the character 0 is used for the number zero and O represents the capital letter o Computer responses and directory paths that do not have variables are written in the font shown here C Program Files Extron Variables are written in slanted form as shown here ping xxx xxx xxx xxx t SOH R Data STX Command ETB ETX Selectable items such as menu names menu options buttons ...

Страница 6: ...olbelt 25 GUI Designer 25 Global Configurator Plus and Professional 25 Global Scripter 25 TLI Pro 101 Web Page 26 Updating the Firmware 27 Downloading Firmware Using Extron Firmware Loader 27 Mounting 29 Tabletop Placement 29 Rack Mounting 29 Underwriters Laboratories Guidelines for Rack Mounting 29 Rack Mounting the TLI Pro 101 29 Under desk Mounting 29 Reference Material 30 Network Port Requirem...

Страница 7: ...TLI Pro 101 Contents vii ...

Страница 8: ...ble with third party touchscreen displays integrates third party touchscreen displays up to 2K or touchpanels with ultra low radiation emission into Extron systems Fast processing and ample memory allows for quicker configuration uploads and more storage for GUI pages Compatible with all IP Link Pro control processors providing control for a wide range of systems Compliant with the requirements of...

Страница 9: ...trol shift return caps lock TCP IP Network Ethernet Ethernet 3rd Party Touch Screen Ethernet USB HDMI HDMI RS 232 RS 232 HDMI HDMI HDMI HDMI HDMI HDMI HDMI HDMI HDMI HDMI Monitor 1 Monitor 2 Monitor 3 Extron DXP 88 HDMI HDMI Matrix Switcher Extron IPCP Pro 350 IP Link Pro Control Processor Blu ray Player PC Laptop Document Camera Video Camera Figure 1 TLI Pro 101 Application Diagram Requirements S...

Страница 10: ...all accounts on this device have been set to the device serial number Passwords can be changed during configuration They are case sensitive NOTE If the device is reset to default settings the passwords are reset to the default password which is extron for either admin or user MAC address make a note of the TLI Pro 101 MAC address 3 Mount the units Stand the TLI Pro 101 on a convenient surface moun...

Страница 11: ... Ethernet subnetwork Use the Setup Menu see page 13 or Toolbelt see the Toolbelt Help File to set the DHCP status and if necessary the IP address subnet mask gateway and related settings for the interface 7 Configure the Interface the Global Configurator Professional and Global Configurator Plus Help File and the GUI Designer Help File provide step by step instructions and detailed information The...

Страница 12: ...Connections TLI PRO 101 LAN PoE USB HDMI HDMI POWER 12 V RESET CONTROL OUTPUT 1 0A MAX INPUT A B G F E C D Figure 2 TLI Pro 101 Rear Panel A Power see page 6 B HDMI Input see page 8 C HDMI Output see page 8 D USB Connector see page 9 E Network and Power over Ethernet PoE Connector see page 10 F Reset mode LED see page 12 G Reset button see page 12 TLI Pro 101 Panel Features 5 ...

Страница 13: ...ced by an incorrect type Dispose of used batteries according to the Instructions ATTENTION Risque d explosion Ne pas remplacer la pile par le mauvais type de pile Débarrassez vous des piles utilisées selon le mode d emploi ATTENTION Do not power on the interfaces or control processors until you have read the Attention on page 7 12 VDC power supply or on page 11 power injector Ne branchez pas les i...

Страница 14: ... les espaces d aération ou dans les cavités murales La source d alimentation doit être située à proximité de l équipement de traitement audiovisuel dans un endroit ordinaire avec un degré 2 de pollution fixé à un équipement de rack à l intérieur d un placard d une estrade ou d un bureau The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI NF...

Страница 15: ...acing Bracket Installation Secure the HDMI connector to the TLI Pro 101 with the provided LockIt HDMI lacing bracket by following these instructions HDMI Type A Receptacle 1 18 2 19 1 Plug the source HDMI cable into this input port 2 Loosen the HDMI connection mounting screw from the TLI Pro 101 rear panel enough to allow the LockIt lacing bracket to be placed over it The screw does not have to be...

Страница 16: ... X X X X X Custom 1 For new resolutions field support only D USB Connector see figure 2 on page 5 Supports High speed USB 2 0 control Plug a USB cable from the third party touchpanel into this female type B connector The USB connection passes information to the TLI Pro 101 about where on the screen the touchpanel was pressed To use a normal monitor instead of a touchscreen connect a mouse to the T...

Страница 17: ...t either power supply before reading the Attention on page 7 or page 11 Le TLI Pro 101 peut utiliser une source d alimentation externe 12 Vcc et est également compatible avec l alimentation POE via Ethernet PoE 802 3af classe 3 Ne branchez pas de sources d alimentation externes avant d avoir lu les mises en garde dans la section Power Supply sur page 7 ou page 11 Use a straight through Ethernet ca...

Страница 18: ...fication de conformité réglementaire Unless otherwise stated the AC DC adapters are not suitable for use in air handling spaces or in wall cavities The power supply is to be located within the same vicinity as the Extron AV processing equipment in an ordinary location Pollution Degree 2 secured to the equipment rack within the dedicated closet podium or desk Sauf mention contraire les adaptateurs ...

Страница 19: ...2 for the interface Setup Menu 1 Press the button briefly less than 2 seconds to open the setup menu screens 2 Press the button briefly for a second time to exit the setup menu Calibration Screen 1 Press and hold the button at least 3 seconds to open the calibration screen Follow the on screen instructions to calibrate the touchpanel 2 Complete the calibration process or press the button briefly l...

Страница 20: ...etwork IP Address DHCP Host Name Off 192 168 254 251 TLI AB CD EF Output Resolution Project Sleep Timer 800x600 N A 5 Minutes Audio Master Volume Master Mute Off 99 Input HDMI Port No Signal Status Output Audio Advanced Exit Network Input Advanced Controller IP N A Project Size N A Figure 7 Status Screen This is a read only screen The Info panel provides basic information about the TLI Pro 101 Eac...

Страница 21: ...twork Screen 1 If IP addresses are assigned by DHCP press On If the IP address is to be assigned manually press Off When DHCP is off the Host Name is grayed out and cannot be edited All addresses can be edited When DHCP is on the Host Name can be edited The addresses are grayed out and cannot be edited because they are set by the DHCP server 2 If DHCP is on press the Host Name button to edit the h...

Страница 22: ... 2 cannot be entered When a valid 3 digit value is entered the next octet is automatically selected c Press OK to save the changes and return to the Network screen or press Cancel to return to the Network screen without saving the changes 4 If you have changed any of the values in the Network screen the background color of the button changes to blue Press Apply to apply the new values or press Rev...

Страница 23: ... the native resolution of the display device Click Project Resolution to use an imported GUI Designer project to set the resolution of the TLI Pro 101 output Click Show More Resolutions for more options TLI Output Resolution and Refresh Rate Resolution List Use EDID Show All OK Cancel Resolution 1280 x 724 1024 x 768 1280 x 720 1366 x 769 1600 x 1200 Refresh Rate Hz 60 Figure 13 TLI Pro 101 Output...

Страница 24: ...es partial energy savings The screen reactivates quickly when it is touched When the display timer is used to deactivate the screen the output sync is disconnected and the screen switches off This provides better energy savings but the screen takes longer to reactivate when it is touched Test patterns The TLI Pro 101 provides eight test patterns which can be used to calibrate the third party touch...

Страница 25: ...r sound volume settings For example if the master volume is set to 80 80 percent of maximum and the the Sound volume is set to 75 the overall Sound volume is 60 of maximum 75 of 80 Click sets the level for audible feedback that accompanies events such as a screen button being pressed Sound sets the audio level from any audio file playback HDMI sets the HDMI audio input level Underneath each slider...

Страница 26: ...e which EDID will be stored by the interface and passed to the video source Match Output default setting The EDID matches the native resolution and refresh rate of the display connected to the HDMI output Project Resolution The EDID is the one set in the GUI Designer project and can be altered only by changing the GUI Designer project file Show More Resolutions Opens a dialog see figure 15 below t...

Страница 27: ...urrent values to be saved as a preset and opens the Presets dialog see figure 16 below Default all Returns the picture values to their default settings Exit Closes the dialog Presets Save Recall Rename Clear Name Input 1 2 3 4 5 6 7 8 HDMI HDMI N A N A N A N A N A N A Blu ray Blu ray 2 Preset 03 Preset 04 Preset 08 Preset 07 Preset 06 Preset 05 Figure 18 Presets Dialog Save Highlight one of the pr...

Страница 28: ...igurator Project Menu Pin Off On Change Figure 19 Advanced Screen System and GUI Project Panels These panels are read only providing information about the system the Global Configurator Project and the GUI Designer Project Menu PIN To prevent unauthorized access to the setup menu users can set a PIN which is a 4 digit number Each digit can have any value from 0 9 The PIN setup options allow you to...

Страница 29: ...ease the button The calibration screen opens to show cross hairs see figure 21 above 3 Press the cross hairs on the screen until they move to another area of the screen 4 Repeat step 3 until you have pressed all five sets of cross hairs one in each corner and one in the center of the screen The touchpanel exits the calibration screen once the calibration process is completed TLI Pro 101 On screen ...

Страница 30: ... Insider account to run Global Scripter or Global Configurator Plus and Professional To obtain one contact the Extron Sales Department The TLI Pro 101 is not compatible with earler Extron software GUI Configurator or Globlal Configurator 3 Ensure you are downloading GUI Designer and Global Configurator Plus and Professional Figure 22 Software Downloads from the Extron Website 1 Open www extron com...

Страница 31: ... in the alphabet menu 3 Downloading software from the product page Clicking on the panels at the top of the page takes you to the software product page on the Extron website Figure 24 shows the GCP product page Figure 24 GCP Product Page To download and install the product click Download 1 and follow the onscreen instructions The software is downloaded and installed on your PC By default the softw...

Страница 32: ... configure a project Toolbelt Use Toolbelt to provide device information firmware updates certificate management and configuration of network settings system utilities reset reboot and user management username and password for TouchLink Pro devices GUI Designer Design the layout of the screen text and graphics using GUI Designer which is a Windows based application You can either customize one of ...

Страница 33: ...ork information about the unit It also allows you to upgrade the unit firmware Use the Setup Menu see page 13 or Toolbelt to configure the network settings of the TLI Pro 101 Extron Electronics General Status Model Name TLI Pro 101 Description TouchLink Pro Interface Part Number 60 1083 01 Firmware Version 1 00 Date Monday May 27 2013 Time 7 58 PM POE On Up Time 0 day s 1 hour s 23 minute s Licens...

Страница 34: ...te Then use Toolbelt or the TLI Pro 101 web page to upload the file to the touchpanel Downloading Firmware Using Extron Firmware Loader 1 The firmware must be downloaded to a PC on the same sub network as the TLI Pro 101 Figure 27 Firmware Download Center 2 Go to www extron com and click Download 1 3 Click Firmware 2 The Download Firmware page opens Figure 28 Selecting Firmware to Download 4 Click...

Страница 35: ... By default it is stored at C Program Files x86 Extron Firmware product name firmware version 10 Use Toolbelt or the Touchpanel web page to upload this file to the touchpanel see the Toolbelt Help File or the following section Updating Firmware Using the Touchpanel Web Page 1 If you have not already done so download the firmware file to a computer on the same network as the touchpanel see the prev...

Страница 36: ... air flow for safe operation Mechanical loading Mount the equipment in the rack so that uneven mechanical loading does not create a hazardous condition Circuit overloading Connect the equipment to the supply circuit and consider the effect that circuit overloading might have on overcurrent protection and supply wiring Give appropriate consideration to the equipment nameplate ratings when addressin...

Страница 37: ...t button is found on the rear panel see figure 2 G on page 5 Use Factory Firmware This mode is used to boot up the unit with factory installed firmware for a single power cycle if a firmware update fails or incompatibility issues arise with user loaded firmware Activation To start the Use Factory Firmware reset mode and replace firmware 1 Remove power from the touchpanel 2 On the touchpanel hold d...

Страница 38: ...actory default Turns DHCP off Reset to Factory Defaults This mode resets all IP settings and touchpanel settings including passwords to factory defaults and removes all configurations It allows you to start over with configuration and uploading NOTES The factory configured passwords for all accounts on this device have been set to the device serial number Passwords can be changed during configurat...

Страница 39: ...u must run Toolbelt as an administrator Some certificates require a passphrase that is created when the certificate is created If a passphrase is required you must enter that passphrase before uploading and applying the certificate These devices support standard OpenSSL certificate encodings such as pem Privacy enhanced Electronic Mail and der Distinguished Encoding Rules file types PEM file types...

Страница 40: ...ntication for the TouchLink Pro control systems DER Distinguished Encoding Rules file types are binary encoded and can typically have several file extension variations such as crt and cer NOTE DER encoded files files with der crt or cer extensions that are encoded in DER binary format must be converted to a PEM encoded file type pem before being used for authentication DER encoded certificates mus...

Страница 41: ...arranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or if modifications were made to the product that were not authorized by Extron NOTE If a product is defective please call Extron and ask for an Application Engineer to receive an RA Return Authorization number This will begin the repair process USA 714 ...

Отзывы: