MGP Pro Series • HTML Configuration and Control
86
3.
Click
Choose
File
, and in the
Open
window (see figure 36) locate the MGP Pro
firmware file on your computer or server. By default, the firmware file is placed at
C:\Program
Files
(x86)\Extron\Firmware\MGPPRO\vn_nn
when the firmware is
installed.
Figure 36.
Choose File to Upload Window
ATTENTION:
Valid firmware files must have the file extension .S19. A file with
any other extension is not a firmware upgrade for this device and could cause the
device to stop functioning.
ATTENTION :
Les fichiers firmware valides doivent contenir l’extension fichier
.S19. Un fichier avec n’importe quelle autre extension n’est pas une mise à jour de
firmware pour cet appareil et l’appareil pourrait arrêter de fonctionner.
4.
Open the firmware file (see figure 36,
1
). The file extension must be
.S19
.
Its name appears below the
Current
Firmware
Version
on the
Firmware
Upgrade
page.
5.
Click the
Upload
button on the
Firmware
Upgrade
page to start the firmware update
process.
While the firmware is being uploaded, the
Upload
button changes to
Uploading...
and the LCD window on the MGP Pro displays
Firmware
Upload
Please
Wait!!!
,
then
Firmware Reboot
Please
Wait!!!
NOTE:
While the firmware is uploading and rebooting, do not press any front
panel buttons or make any selections on the web pages.
When the uploading process is complete, the
Uploading...
button on the screen
changes back to
Upload
.
36