IPL Pro Series • Hardware Features and Installation
22
IPL Pro Series Control Processor Reset Mode Summary
Mode
Use This
Mode to...
Activation
Result
Pr
oject Recovery
Recover
project
configuration
and program
files if
passwords
have been lost
For devices with firmware version 1.04 and lower
To start the Project Recovery reset mode and recover a project:
1.
On the PC, open Global Configurator.
2.
Click the
Tools
menu and select
Project Recovery
. The
Recovery Mode
dialog box opens.
3.
Enter the IP address or host name of the target device for
which you want to perform project recovery.
4.
Click
Recover
. The software allows indefinite time to
establish a connection (until a connection is made or the user
clicks
Cancel
).
5.
On the control processor, hold down the recessed
Reset
button while applying power to the unit. Hold the button down
until the Power LED blinks twice, then release the button.
The control processor enters project recovery mode for
20 seconds, during which time the
Power
LED blinks quickly.
GC automatically connects to the control processor, then
opens and retrieves the project from the unit.
6.
Cycle power to the control processor to exit project recovery
mode.
7.
Perform the
Reset to Factory Defaults
reset on the control
processor.
8.
Open Toolbelt, start device discovery, select the desired
control processor from the list and click
Manage
.
9.
Click the
Network Settings
tab and set the IP address of
the control processor.
10.
Click the
User Management
tab and change the password
of the control processor.
11.
Close Toolbelt.
12.
In GC, add the new password to the recovered project.
13.
Save the project.
14.
Upload the project from GC to the control processor.
Project Recovery mode stops regular
operation and allows a connection to be
made to the unit via GC software without
requiring password entry so that project
files can be retrieved and saved.
•
During product recovery mode, events are
stopped, and so is communication with AV
devices.
•
While the control processor is in this mode,
use the GC software to recover project
files.
•
If the software does not initiate project
recovery within 30 seconds after the
control processor enters this mode, the
control processor exits recovery mode.
•
Upon exiting project recovery mode:
•
The unit returns to its pre-recovery
mode state and settings.
•
The Power LED returns to being
steadily lit.
For devices with firmware version 1.05 and higher
To start the Project Recovery reset mode and recover a project:
1.
On the PC, open Global Configurator.
2.
Click the
Tools
menu and select
Project Recovery
. The
Recovery Mode
dialog box opens.
3.
Enter the IP address or host name of the target device for
which you want to perform project recovery.
4.
Click
Recover
. The software allows indefinite time to
establish a connection (until a connection is made or the user
clicks
Cancel
).
5.
On the control processor, press the
Reset
button three
times within one second. The control processor enters
project recovery mode for 30 seconds, during which time the
Power
LED blinks quickly.
GC automatically connects to the control processor, then
opens and retrieves the project from the unit.
6.
Cycle power to the control processor to exit project recovery
mode.
7.
Perform the
Reset to Factory Defaults
reset on the control
processor.
8.
Open Toolbelt, start device discovery, select the desired
control processor from the list and click
Manage
.
9.
Click the
Network Settings
tab and set the IP address of
the control processor.
10.
Click the
User Management
tab and change the password
of the control processor.
11.
Close Toolbelt.
12.
In GC, add the new password to the recovered project.
13.
Save the project.
14.
Upload the project from GC to the control processor.
Project Recovery mode stops regular
operation and allows a connection to be
made to the unit via GC software without
requiring password entry so that project
files can be retrieved and saved.
•
During project recovery mode, events are
stopped, and so is communication with AV
devices.
•
While the control processor is in this mode,
use the GC software to recover project
files.
•
If the software does not initiate project
recovery within 30 seconds after the
control processor enters this mode, the
control processor exits recovery mode.
•
Upon exiting project recovery mode:
•
The unit returns to its pre-recovery
mode state and settings.
•
The
Power
LED returns to being
steadily lit.