IPL Pro Series • Hardware Features and Installation
16
Bidirectional Control and Communication Connections and Features
B
5-pole COM ports, RS-232/RS-422*/RS-485*
(see
figure 7
, on page 13)
— Use COM ports for serial control of a display
or other device and to receive status messages
from the connected devices. These ports can
send commands from a driver file. RS-232 is
the default mode of operation.
IPL Pro Series serial protocol:
•
300 to 115200 baud (9600 baud = default)
•
8 (default) or 7 data bits
•
1 (default) or 2 stop bits
•
No parity (default), even, or odd parity
•
Flow control support (default = none):
hardware and software (XON, XOFF)
*Supported serial formats vary depending on
the model and the COM port, as shown at
right.
Use the following diagram as a wiring guide to
cable the IPL to other devices.
G
Tx Rx
RTSCTS
COM 1
G
Tx Rx
RTSCTS
COM 4
COM
3
1
2
6
4
5
RTS
CTS
Tx
Rx
COM
RTS
CTS
Tx
Rx
NOTE:
If you use cable that has a drain wire, tie the drain wire to ground at both ends.
Strip wires
3/16" (5 mm)
max.
Receive (Rx)
Transmit (Tx)
Projector, Panel
Display, PC, or
Other RS-232,
RS-422, or
RS-485 Device
Request to send
Clear to send
Transmit
Rx
Receive
Tx
CTS
RTS
G
Ground
T
T
Tx
T
R
Front Panels
Select protocol via software.
COM port default protocol:
• 9600 baud
• 8 data bits • 1 stop bit
• no parity
• no flow control
NOTE:
The 5-pole COM ports support both
hardware and software flow control.
Heat Shrink
Heat Shrink
Over Shield Wires
To 5-pole
COM port
RTS = Request to Send
CTS = Clear to Send
Tx = Transmitting Data
Rx = Receiving Data
Serial (COM) Ports
Rear Panels
5-pole COM
(RS-232, RS-422*, RS-485*)
*See the Serial Options
table for which port
supports which standards.
RS-232
Tx
Rx
Ground
RTS
CTS
RS-422*
Tx-
Rx-
Ground
Tx+
Rx+
RS-485*
Ground
5-pole COM Pin Configurations
Data-
(pins 1 & 2
tied together)
Data+
(pins 4 & 5
tied together)
Pin
1
(Tx)
2
(Rx)
3
(G)
4
(RTS)
5
(CTS)
*See the Serial Options table of supported
formats for each port.
Figure 9.
Wiring COM ports for Serial Control
For bidirectional serial communication, the transmit, ground, and receive pins must be wired
at both the IPL Pro Series and the other device. Each projector or other device may require
different wiring. For details, see the manual for that equipment or read the Extron device
driver communication sheet, which is included with the drivers.
NOTE:
Maximum distances between the IPL and the device being controlled are generally
up to 200 feet (61 m) but may vary based on factors such as cable gauge, baud rates,
environment, and output levels (from the IPL and the device being controlled).
3/16"
(5 mm)
Max.
7/8"
(22 mm)
Heat Shrink
on Outer
Jacket to
Inner
Conductor
Transition
Extron
STP 20-2P Cable
TIP:
STP 20-2P
cable, shown
at left, is
recommended
for these
connections.
For best
results,
insulate the
common or
drain wires
using heat
shrink.
RS-232
Only
RS-232, RS-422,
or RS-485
Serial Options
Model
COM Port
1
IPL Pro S1
1
2, 3
IPL Pro S3
1
2, 3, 4, 5, 6
IPL Pro S6
Содержание IPL Pro CR88