Step 8: Mount the EBPs

Prior to mounting:

1. 

If it has not already been done, feed all device cables through the wall or furniture and, if applicable, through the plastic spacer.

NOTE:

  If the unit is not installed in a mud ring, you must install the plastic spacer. The spacer positions the unit to allow 

the magnetic faceplate to attach properly and securely.

2. 

Ensure that cables are connected to the EBP rear panel.

Mount the EBP as follows:

1. 

Insert the cabled EBP into the mud ring or junction box within the wall or furniture, aligning the mounting holes in the EBP 
with those in box or mud ring.

2. 

Secure the EBP to the junction box, wall or surface mounting box, 
or mud ring as follows (see 

1

 in figures 7 and 8): 

a. 

Insert the included screws through the oval slots at 
the top and bottom of the EBP, through the 
plastic spacer (if not using a mud ring), 
and into the corresponding threaded 
holes in the box or mud ring.

b. 

Using a Phillips screwdriver, lightly 
tighten the screws until snug. 

Extr

on

DIS

PLA

Y

VOLU

ME

2

2

1

1

EBP 100 

Wall Mounting
Bracket
(Mud Ring)

Faceplate

Wall

3. 

Attach the faceplate to the EBP: align the faceplate openings with the buttons, knob, and LEDs and place the faceplate 
against the unit (see 

2

 in figures 7 and 8). The magnetic catches fasten the faceplate onto the front of the unit.

3. 

Disconnect power at the source from all devices in the system.

Extr

on

DIS

PLA

Y

VOLU

ME

2

2

1

1

Wall

Wall

 Box

Faceplate

EBP 100 

Plastic Spacer 

Figure 7. 

Installing the EBP 
in a Junction Box

Figure 8. 

Installing the EBP  
in a Mud Ring

Содержание EBP 100

Страница 1: ...tting bus ID DIP switches on the EBPs then using Extron Global Configurator GC Plus and Professional software or Global Scripter programming to configure the control processor Once configured the AV system can be controlled from any of its EBPs This guide provides basic instructions for an experienced installer to install an EBP 100 or EBP 200 button panel For more details on the EBPs see the EBP ...

Страница 2: ...e Installation Site ATTENTION Installation and service must be performed by authorized personnel only L installation et l entretien doivent être effectués par le personnel autorisé uniquement Extron recommends installing the EBP into a grounded UL Listed electrical junction box Extron recommande d installer le EBP dans un boîtier d encastrement électrique mis à la terre listé UL If the EBP will be...

Страница 3: ...late with the other hand and pulling the faceplate away from the unit 2 Gently separate the button lens button cap from its white diffuser insert the end of the provided Extron removal pry tool into the corner notch and gently twist the tool see 1 in the image at right 3 Remove the label insert from the button cap 4 Select one of the button labels from the printed label sheets included with the un...

Страница 4: ...EBP 100 Rear Panel eBUS port on an IPCP Pro or on an EBP or other eBUS endpoint Figure 3 Rear Panel Features Including DIP Switch Location and Settings Each EBP in a system must have a different unique bus ID address a six bit binary number which you set by using the DIP switch assembly on the rear panel of each EBP Switch 1 on the left sets the most significant bit highest number 32 Switch 6 sets...

Страница 5: ...rtifiée UL de classe 2 ou LPS et paramétré à 12 VDC et 1 0 A minimum Unless otherwise stated the AC DC adapters are not suitable for use in air handling spaces or in wall cavities Sauf mention contraire les adaptateurs AC DC ne sont pas appropriés pour une utilisation dans les espaces d aération ou dans les cavités murales The installation must always be in accordance with the applicable provision...

Страница 6: ...device drivers and link them to each assigned port Configure settings serial protocol relay behavior digital input volume control settings as needed b Set up monitors schedules macros and local variables c Set up the eBUS button panel buttons assign appropriate commands and actions macros timers local variables monitors or feedback to the buttons 2 Save the project 3 Build and upload the system co...

Страница 7: ...x wall or surface mounting box or mud ring as follows see 1 in figures 7 and 8 a Insert the included screws through the oval slots at the top and bottom of the EBP through the plastic spacer if not using a mud ring and into the corresponding threaded holes in the box or mud ring b Using a Phillips screwdriver lightly tighten the screws until snug Extron DISPLAY VOLUME 2 2 1 1 EBP 100 Wall Mounting...

Страница 8: ... FAX Extron Asia 65 6383 4400 65 6383 4664 FAX Extron Japan 81 3 3511 7655 81 3 3511 7656 FAX Extron China 86 21 3760 1568 86 21 3760 1566 FAX Extron Middle East 971 4 299 1800 971 4 299 1880 FAX Extron Australia 61 8 8351 2188 61 8 8351 2511 FAX Extron India 1800 3070 3777 Inside India Only 91 80 3055 3777 91 80 3055 3737 FAX 2016 Extron Electronics All rights reserved All trademarks mentioned ar...

Отзывы: