Installation and Operation, cont’d
DVS 304 • Installation and Operation
2- 22
Front Panel Lockout (Executive mode)
To prevent accidental changes to settings, press the Menu and Next buttons
simultaneously for 2 seconds to enable the DVS 304’s front panel lockout mode,
also known as executive mode.
Executive mode locks all front panel functions except input switching and preset
recall. The menu system returns to the default menu within 10 seconds. The
DVS 304’s front panel is affected by executive mode, but the IR 902 remote is not
(see “IR 902 Infrared Remote Control” later in this chapter for more information).
When executive mode is active, all functions and adjustments can still be made
through RS-232 control. For details on RS-232 control, see chapter 3,
Serial
Communication
.
To disable the executive mode, press the Menu and Next buttons simultaneously
for 2 seconds. See the flowchart below.
Menu
Press for
2 seconds*
Next
EXE MODE
ENABLED
Enable Executive Mode
10 sec.
timeout
EXE MODE
DISABLED
Disable Executive Mode
2 sec.
INPUT 1
COMPOSITE
OUTPUT
1024 x 768@60
Default Cycle
2 sec.
Menu
Press for
2 seconds*
Next
10 sec.
timeout
2 sec.
INPUT 1
COMPOSITE
OUTPUT
1024 x 768@60
Default Cycle
2 sec.
Figure 21 — Front Panel Lockout