ExtraHop 8.8 ExtraHop Trace Admin UI Guide
44
SNMP System Contact
Type a valid name or email address for the SNMP system contact.
SNMP System Location
Type a location for the SNMP system.
3. Click
Save Settings
.
Next steps
Download the ExtraHop MIB file from the SNMP Service Configuration page.
Firmware
The Administration settings provide an interface to upload and delete the firmware on ExtraHop appliances.
The firmware file must be accessible from the computer where you will perform the upgrade.
Before you begin
for the firmware version that you want to install. Release notes contain
upgrade guidance as well as known issues that might affect critical workflows in your organization.
Upgrade the firmware on your ExtraHop system
The following procedure shows you how to upgrade your ExtraHop system to the latest firmware
release. While the firmware upgrade process is similar across all ExtraHop appliances, some appliances
have additional considerations or steps that you must address before you install the firmware in your
environment. If you need assistance with your upgrade, contact ExtraHop Support.
Pre-upgrade checklist
Here are some important considerations and requirements about upgrading ExtraHop appliances.
•
A system notice appears on Command and Discover appliances connected to ExtraHop Cloud Services
when a new firmware version is available.
•
Verify that your Reveal(x) 360 system has been upgraded to version 8.7 before upgrading your self-
managed sensors.
•
If you have multiple types of ExtraHop appliances, you must upgrade them in the following order:
1. Command appliance
2. Discover appliances
3. Explore appliances
4. Trace appliances
•
If you have a Command appliance, apply the following guidance:
•
For large Command appliance deployments (managing 50,000 devices or more), reserve a
minimum of one hour to perform the upgrade.
•
The Command appliance firmware version must be greater than or equal to the firmware version
of all connected appliances.
•
If you have Explore appliances, apply the following guidance:
•
Do not upgrade Explore appliances to a firmware version that is newer than the version installed
on connected Command and Discover appliances.
•
After upgrading the Command and Discover appliances, halt the ingest of records from the
Command and Discover appliances before upgrading the Explore appliance. If you are upgrading
from a firmware version prior to 7.4, temporarily
remove any connected Explore appliances
,
or alternatively,
that commit records and disable the
setting. If you are upgrading from firmware version 7.4 or later, after upgrading the Command
disable record ingest on the Explore cluster
before upgrading the Explore
appliance.
You must re-enable these settings after all nodes in the Explore cluster are upgraded.
Содержание Trace Admin UI