37
ENGLISH
* on models with this function.
ALARMS
DISPLAY
EXPLANATION
SOLUTION
Indicates the presence of an alarm.
On: indicates the presence of an alarm
Flashing: indicates the deactivation of the depression sensor.
The alarm can be reset only if the fumes motor has stopped and 15 minutes have
passed since the alarm was displayed, by pressing the key 1/
for 3 seconds.
FUMES MOTOR
FAULT
Fumes motor fault
Contact after-sales centre
FUMES PROBE
Fumes probe fault.
Contact after-sales centre
HOT FUMES
High fumes temperature
Check pellet feed (see “Easy setup”), if the problem cannot be solved,
contact a qualified technician.
NO
IGNITION
The pellet hopper is empty.
Pellet feed calibration inadequate.
Check for the presence of pellets in the hopper.
Adjust the pellet flow (see “Easy setup”).
Check the procedures described in the “Ignition” chapter.
NO FLAME
The pellet hopper is empty.
No pellet feed.
The gearmotor does not feed pellets.
Check for the presence of pellets in the hopper.
Adjust the pellet flow (see “Easy setup”).
DEPR ALARM
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The fumes exhaust pipe is blocked/dirty
The air intake pipe is blocked/dirty
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe and the combustion chamber.
Check/clean air inlet.
* TRAPDOOR BLOCKED
The automatic cleaning of the burn pot is
blocked.
Burn pot dirty/clogged
The door is not closed correctly.
The ash drawer is not closed correctly.
Check that the door closes correctly.
Check that the burn pot is clear and clean. The automatic cleaning of the
burn pot is blocked.
If the problem persists, contact the service centre.
Check hermetic closure of the ash drawer.
* PRESSURE SENSOR
DAMAGE
Differential pressure sensor faulty, disconnected
or broken.
Contact after-sales centre
* AUGER CONTROL
ALARM
Abnormal pellet feeding.
Contact after-sales centre
* AUGER BLOCKED
Abnormal operation of pellet motor.
Contact after-sales centre
* EMPTY HOPPER
The pellet hopper is empty.
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The fumes exhaust pipe is blocked.
Check for the presence of pellets in the hopper.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe, of the sensor in the primary air
channel and the combustion chamber.
Contact after-sales centre
MAX ELECTRICAL CUR-
RENT
The automatic cleaning of the burn pot is
blocked.
Burn pot dirty/clogged
The door is not closed correctly.
Check that the door closes correctly.
Check that the burn pot is clear and clean.
The automatic cleaning of the burn pot is blocked.
If the problem persists, contact the service centre.
CLOSE
HOPPER - STOVE DOOR
Pellet hopper open.
Door open.
Air inlet clogged or dirty.
Make sure that the pellet hopper, door and ash drawer close properly.
Check air inlet.
CHAMB PROBE
Chamber probe fault.
Contact the after-sales centre.
TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE WEBSITE WWW.LANORDICA-EXTRAFLAME.COM