29
ENGLISH
DELAY SWITCH-OFF
You can program a delayed switch-off for the stove. For example, if it is 8 pm and the delayed switch-off is set to 1h, the stove will automatically
switch off at 9 pm.
If you press and hold keys 6 + 2 at the same time, the screen “DELAY SWITCH-OFF” will appear,
(
this setting can only be configured if the
stove is in the
PREPARATION
or
WORK
phase
).
Use keys 2 and 3 to increase/decrease the number of hours after which the stove will automatically start the final cleaning phase.
The number of hours range from OFF, 1 to 9.
Press P6 to confirm and return to the Home page.
One hour after the set switch-off time, the remaining operating time is indicated by displaying at one-minute intervals “switch off in” and
the time “HOURS xx:xx”.
INSTALLATION MUST BE PERFORMED BY QUALIFIED STAFF AND/OR THE MANUFACTURER'S SERVICE TECHNICIANS
ADDITIONAL FUNCTIONS
SUPPLEMENTARY THERMOSTAT INSTALLATION (OPTIONAL)
The stove can control the room temperature through a supplementary thermostat (optional).
After ignition (by pressing key 1 or in chrono mode), the stove will work to reach the set value on the thermostat, displaying WORK (closed
contact) on the screen. The standard room sensor is by-passed automatically.
When the thermostat temperature has been reached (open contact), the stove switches to minimum power level and displays MODULATION
ON THE SCREEN.
CONTROLS PROCEDURE
A mechanical or digital thermostat with a “normally open” input is required.
Remove the plug from the socket.
Using the figure to the side as a reference, connect the two thermostat cables (clean contact
- no 230 V!).
Connect the power to the stove again.
Press key 3, until the
SET THERMOSTAT
is on
LOW-TA
.
PLEASE NOTE: THE TERMINAL CAN BE FOUND IN THE BAG INSIDE THE STOVE.
DEPRESSURE NOTICE
It allows you to activate the buzzer for acoustic warnings if the door or the hopper are open.
Please note: Activation can reduce battery life by 30%.
The battery life depends on the usage
To set:
OK > SETTINGS > DEPRESSURE NOTICE