27
ENGLISH
STAND BY
The STAND BY function is used if the stove needs to be turned off immediately instead of a power modulation.
To set:
OK > SETTINGS> STAND BY.
DATE-TIME
LANGUAGE
SET DEGREES
SEE CHAPTER: FIRST IGNITION SETTINGS.
J
FOR CORRECT OPERATION, THE SET THERMOSTAT MUST BE SET TO LOW-TA.
> SEE THE SUPPLEMENTARY THERMOSTAT INSTALLATION CHAPTER
SETTINGS
DISPLAY
The "
DISPLAY
" menu allows:
Regulation of Display contrast.
Activation/Deactivation of backlight.
Enabling/disabling of acoustic signal.
Setting of the timer to turn off the Display backlight.
Setting of the timer to turn off the Display (sleep mode).
To set:
OK > SETTINGS > DISPLAY.
STAND BY FUNCTION SET TO ON
If the
STAND BY
function is enabled (ON) and the ambient temperature exceeds the
SET THERMOSTAT
+
DELTA-T OFF
value, then the stove
switches off after a preset factory delay, and
STAND BY
will be displayed on the screen.
When the room temperature is lower than the
SET THERMOSTAT
-
DELTA-T ON
and after a possible cooling time, the stove switches back on.
STAND BY FUNCTION SET TO OFF (FACTORY SETTING)
When the STAND BY function is not enabled (OFF), if the stove exceeds the set ambient temperature, it will switch to the minimum power
level, modulating and displaying
MODULATION
on the screen. When the room temperature is lower than the SET THERMOSTAT the stove
will restart at the set power and
WORK
will be displayed on the screen.
OPERATION WITH ADDITIONAL THERMOSTAT (OPTIONAL)
STAND BY FUNCTION SET TO OFF (FACTORY SETTING)
When the STAND BY function is not activated (OFF), if the stove exceeds the room temperature set on the supplementary thermostat (open
contact), it switches to the minimum power level and displays MODULATION on the screen. When the ambient temperature is lower than the
set value on the additional thermostat (closed contact), the stove will resume operation at the set power, and WORK will be displayed on the
screen.
STAND BY FUNCTION SET TO ON
If the STAND BY function is activated (ON), when the room temperature set on the supplementary thermostat is reached (open contact), the
stove will switch off after a pre-set default delay period, and STAND BY will be displayed on the screen.
When the ambient temperature is less than the set temperature on the additional thermostat (closed contact), and after a certain cooling time,
the stove ignites again.