66
Chapter 9
ELECTRONIC CONTROL UNIT
Collector temperature indication
COL:
Collector temperature
Setting area: -40 ... +250 °C
Indicates the current temperature of the
collector
COL: collector temperature
Tank temperature indication
SER, SERI, SERS:
Tank temperature
Setting area: -40 ... +250 °C
Indicates the current temperature of the tank.
SER: tank temperature
SERI: lower tank temperature
SERS: upper tank temperature
Indications of probes 3 and 4
S3, S4:
Temperature probe
Setting area: -40 ... +250 °C
Indicates the current temperature of the
respective additional probe (without
function in the regulator).
S3: temperature probe 3
S4: temperature probe 4
Note: S3 and S4 are displayed only if the
temperature probes are attached.
Indication of the other temperatures
TRIT:
Other measurement
temperatures
Setting area: -40 ... +250 °C
Indicates the current temperature of the
respective probe.
TRIT: return temperature.
Working hour counter
h P / h P1 / h P2:
Display channel working
hours counter
The working hours counter adds the solar
working hours of the respective relay (h P/h
P1/h P2). The display indicates complete
hours.
The summed working hours can be reset
at zero. Once a working hours channel has
been selected, SET appears constantly on
the screen. To pass to the counter RESET
mode, press the SET key for 2 seconds. SET
fl ashes and the working hours are reset at
0. To end the RESET operation, do not press
any keys for 5 seconds. The regulator passes
automatically to the initial display mode.