Chapter 9
ELECTRONIC CONTROL UNIT
INSTALLATION
ASSEMBLY
ATTENTION!
always make sure that the network voltage is
completely disconnected before opening the
casing.
Assembly must be carried out exclusively in closed, dry
environments. To guarantee regular functioning, make sure
there are no strong electromagnetic fi elds in the place of
installation. The regulator must e able to be separated from
the electrical mains by means of an additional device with
a minimum disconnection distance on all poles of 3mm), or
by means of a disconnection device in compliance with the
laws in force. Pay attention in the installation phase that the
connection cable to the electric mains and the probe cable
remain separate.
Loosen the mask screws crosswise and detach this
1.
from the casing by removing it downwards.
Mark the upper fi xing point for suspension and
2.
pre-assemble the plug using the corresponding screw
included in the supply.
Attach the casing in the upper fi xing point and mark
3.
the lower fi xing point (distance between holes: 130 mm);
insert the lower plug.
Attach the casing at the top and fi x it using the lower
4.
screw.
The input of electric current to the regulator must pass
through an external switch (last stage of assembly!) and
the electric voltage must be 220 ...240 V~ (50 ...60 Hz). The
fl exible cables must be fi xed to the regulator lid using the
relative brackets and screws to allow strain relief or put into
the channel in the regulator box. Depending on the version
the regulator is equipped with 1 relay (CS 3.1) or 2 relays
(CS 3.2), to which utilities such as pumps, valves etc. can be
connected:
Relais 1
18 = wire R1
17 = neutral wire N
13 = earth clamp
Relais 2 (only CS 3.2)
16 = wire R2
15 = neutral wire N
14 = earth clamp
The temperature probes (S1 to S4) must be connected with
indiff erent polarities to the following clamps:
Display
Mask
Cable passage with
strain relief
Buttons
Fuse
Suspension
Fixing
ELECTRIC ATTACHMENT
CS 3.1
CS 3.2
Fuse
Probe clamps
Earth clamps
User clamps
Clamps
for attachment to the
electric network
Fuse
Probe clamps
Earth clamps
User clamps
Clamps
for attachment to the
electric network
fi gure 9.5
fi gure 9.6
Содержание BSV 150 ES
Страница 1: ...SOLAR KIT INSTALLATION MANUAL ...
Страница 2: ...2 ...
Страница 6: ...6 Chapter 1 WARNINGS AND SAFETY DEVICES figure 1 1 figure 1 2 ...
Страница 55: ...55 HYDRAULIC SYSTEM Chapter 8 figure 8 12 figure 8 13 figure 8 14 figure 8 15 ...