ELECTRONIC CONTROL UNIT
Chapter 9
Troubleshooting
If there is interference inside the regulator, the display
will communicate it with the following warning:
T4A fuse
Warning symbols
Control indicator
indicator
Problem
Reason
Solution
The regulator control
indicator led is always
off .
The regulator is not powered.
Check the regulator power supply.
Check the fuse and replace it if
necessary.
The control indicator
fl ashes red intermittently.
The symbol appears on
the display (spanner)
and the symbol (triangle)
fl ashes.
Faulty probe. 888.8 appears in the
corresponding channel instead of a
temperature, meaning that the probe
is broken or disconnected.
Check the probe. The attached Pt
probes can be controlled using a
polimeter. Their temperatures can be
compared with the resistance values
stated in the following table.
Faulty probe. -88.8 appears in the
corresponding channel instead of a
temperature, meaning that the probe
is short circuited.
Check the probe. The attached Pt
probes can be controlled using a
polimeter. Their temperatures can be
compared with the resistance values
stated in the following table.
The solar circuit pump
does not work even if
the collector is much
hotter than the tank.
The regulator control indicator is off .
Check the regulator power supply and
the fuse.
The solar circuit pump
does not function even
in manual mode.
Voltage has not reached the pump.
Check the power supply of the
regulator, the pump and the fuse.
The pump is blocked.
Release the pump rotor using a
screwdriver.
fi gure 9.17
fi gure 9.18