33
ALARMS
Display D1
Message
Cause
Solution
Indicates the presence of an alarm
This indicator lights up when one of the alarms
described below is in progress and is accompanied by
the corresponding indication on display D1. To reset the
alarm, press button 1 and hold for three seconds when
the stove is completely cold.
Fum Fail
The exhaust motor is blocked.
The speed control probe is faulty.
No power supply to the exhaust
motor.
All restore operations must be carried out by an
authorised technician.
Fumi tc
The exhaust fume probe is broken.
The
exhaust
fume
probe
is
disconnected from the board.
All restore operations must be carried out by an
authorised technician.
High Temp
The blower is faulty.
Excessive pellet feed.
No power supply to the fan.
Adjust the flow of pellets (see
“Pellet Feed
Adjustment”).
Other restore operations must be carried out by
an authorised technician.
Depr Fail
The exhaust pipe is obstructed.
The combustion chamber is dirty.
The pressure sensor is faulty.
The ash drawer is not closed
properly.
The door is not closed properly.
Check to make sure that the exhaust outlet and the
combustion chamber are clean.
Check to see if the drawer is closed properly.
Check to see if the door is closed properly.
Other restore operations must be carried out by
an authorised technician.
No Acc
The pellet hopper is empty.
The spark plug is faulty or out of
position.
Inadequate pellet feed setting.
Check the level in the pellet hopper.
Check the procedures described in “
Lighting”.
Adjust the flow of pellets (see
“Pellet Feed Adjustment”)
Other restore operations must be carried out by
an authorised technician.
No Acc / Blac Out
No electricity during the lighting
phase.
Press button 1 to switch off the stove and repeat the
procedure described in “
Lighting”.
No pell
The pellet hopper is empty.
Pellet feeding is insufficient.
The feed motor still has to settle in.
The gearmotor is not loading pellets.
Check the level in the pellet hopper.
Adjust the flow of pellets (see
“Pellet Feed
Adjustment”).
Other restore operations must be carried out by
an authorised technician.
Atte + alarm
An attempt is made to reset an alarm
white the stove is still cooling.
Whenever one of the alarms described above is tripped,
the stove automatically shuts down.
During this phase, any attempt to reset the alarm will
be blocked, and the display will show the alarm and
“ATTE” in alternation.
Resetting the alarm by pressing button 1 is only possible
after the stove has completely shut down.
Nr. Telephone
- - - - - - - - - -
Display
of
the
service
centre
telephone number.
When an alarm occurs, the type of alarm detected and
the telephone number of the service centre flash on the
display in alternation.
If the number has not been entered, the display shows
a series of dashes.
Содержание BABYFIAMMA
Страница 27: ...27 ...
Страница 40: ...40 14 WIRING DIAGRAM General wiring diagram ...
Страница 41: ...41 Maxi Comfort Insert wiring diagram ...