![Extraflame BABYFIAMMA Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/extraflame/babyfiamma/babyfiamma_instruction-manual_2454185049.webp)
49
4. CLEANING THE HEA
T EXCHANGER (monthly)
The heat exchangers chamber has to be cleaned once a
month because the ash residue doesn’t let the stove work
properly. To do this, it is necessary to remove the firewall:
•
Remove the brazier from his frame
•
Rotate the door latch of 180° like in picture 7.
•
Take the cast iron and rotate it down.
•
Remove it from the combustion chamber by pulling it.
Pay attention to the two lateral cast iron levers.
Once the heat exchangers chamber is accessible, scrape with
the ash hook to remove the deposited residues and scrape off
any encrustation. Finally use vacuum cleaner to complete the
cleaning (picture 9). After that p
r
oceed in the inverse order to
reassemble and rotate the door latch of 180° to have it in the
original position.
Picture 6
Picture 7
Picture 8
Picture 9
5
. DOOR, ASH DRAWER AND BURN POT SEALS
The seals ensur
e that the stove is hermetically sealed and consequently that it operates correctly.
The seals should be checked periodically and replaced immediately if worn or damaged.
These operations must be car
ried out by an authorized technician.
N.B.: To ensure correct operation, the stove should have general maintenance
performed at least once a year by an authorized technician.
If the power cable is damaged, it must only be replaced by the service centre or by a qualified
technician, in order to avoid any risks.
Содержание BABYFIAMMA
Страница 27: ...27 ...
Страница 40: ...40 14 WIRING DIAGRAM General wiring diagram ...
Страница 41: ...41 Maxi Comfort Insert wiring diagram ...