5. ASSEMBLY AND INSTALLATION INSTRUCTIONS
The installation must comply with:
UNI 10683 (2005) heat generators fed with wood and other solid fuels: installation.
The chimneys must comply with:
UNI 9731 (1990) chimneys: classification according to thermal resistance.
UNI 9615 (1995) calculation of the internal dimensions of the chimneys with single connection.
UNI 7129 point 4.3.3 provisions, local rules and prescriptions of the fire brigade.
UNI 1443 (2005) chimneys: general requirements.
UNI 1457 (2004) chimneys: internal ducts in terracotta and ceramics.
5.1 Glossary
CLOSED HEARTH DEVICE
Heat generator that can only be opened to load fuel during use.
BIOMASS
Material of organic origin, excluding the material incorporated in geological formations and
fossilised.
BIOFUEL
Fuel produced directly or indirectly from biomass.
FLUE or CHIMNEY
Vertical duct for collecting and expelling combustion products from a single appliance at a suitable
height from the floor.
EXHAUST CHANNEL OR PIPE
Duct or connecting element between the heat generating device and the chimney for extracting
the combustion products.
INSULATION
The series of measures taken and materials used to prevent heat transmission through a wall
dividing rooms at different temperatures.
CHIMNEY CAP
Device located at the top of the chimney that facilitates dispersion of the combustion products in
the atmosphere.
CONDENSATE
Liquid products that form when the temperature of the combustion gas is lower than or equal to
the dew point of the water.
HEAT GENERATOR
Device that permits the production of thermal energy (heat) by the rapid transformation of the
chemical energy of the fuel by means of combustion.
AIR LOCK
Mechanism for modifying the dynamic resistance of the combustion gasses.