background image

RH210-en-GB_V1.0   12/14 

3

1
2

3

4

5

6

7

8

9

Meter

 

Description

 

 

1.

 

Humidity

 

or

 

Dew

 

Point

 

reading

 

2.

 

Temperature

 

reading

 

3.

 

Power

 

button

 

4.

 

Data

 

Hold

 

button

 

5.

 

Record

 

button

 

6.

 

Function

 

button

 

7.

 

Probe

 

connection

 

8.

 

SET

 

button

 

(under

 

flap)

 

9.

 

Probe

 

 

 

 

 

 

 

 

NOTE:

 

Battery

 

compartment

 

on

 

back

 

of

 

meter

 

 

Meter

 

Power

 

The

 

meter

 

is

 

powered

 

by

 

one

 

9V

 

battery;

 

press

 

the

 

Power

 

button

 

to

 

switch

 

the

 

meter

 

ON.

 

Press

 

and

 

hold

 

the

 

Power

 

button

 

for

 

at

 

least

 

2

 

seconds

 

to

 

switch

 

the

 

meter

 

OFF.

 

When

 

powering

 

ON,

 

the

 

meter

 

performs

 

a

 

self

test

 

whereby

 

the

 

LCD

 

display

 

counts

 

down

 

to

 

zero

 

before

 

stabilizing

 

at

 

the

 

normal

 

operation

 

screen.

 

If

 

the

 

meter

 

does

 

not

 

switch

 

ON

 

when

 

prompted,

 

or

 

if

 

the

 

low

 

battery

 

icon

 

is

 

showing

 

on

 

the

 

LCD,

 

please

 

replace

 

the

 

battery.

 

Refer

 

to

 

the

 

battery

 

installation

 

section

 

for

 

detailed

 

information.

 

The

 

Auto

 

Power

 

OFF

 

feature

 

switches

 

the

 

meter

 

OFF

 

after

 

a

 

10

minute

 

period

 

of

 

inactivity.

 

To

 

defeat

 

this

 

feature

 

please

 

refer

 

to

 

the

 

Setup

 

Mode

 

section.

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание RH210

Страница 1: ...User Guide Hygro Thermometer Model RH210 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...for the latest version of this User Guide Features Air Temperature Relative Humidity and Dew point measurements Detachable probe for ease of use in a variety of measurement environments Fast humidity...

Страница 3: ...at least 2 seconds to switch the meter OFF When powering ON the meter performs a self test whereby the LCD display counts down to zero before stabilizing at the normal operation screen If the meter do...

Страница 4: ...display icon will switch OFF MIN MAX Recording When selected the Data Recording function records the MIN lowest and MAX highest readings 1 Press the REC button once to start recording MIN and MAX rea...

Страница 5: ...press the Function button so that the number 1 appears and then press REC 3 To select C press the Function button so that the number 0 appears and then press REC 4 Press the HOLD button to save the se...

Страница 6: ...apping the battery terminals onto the wired connectors observing correct polarity and inserting the battery into the compartment 6 Install the battery chamber into the meter housing and secure with th...

Страница 7: ...nsions Meter 135 x 60 x 33mm 5 3 x 2 4 x1 3 Probe 197mm 7 8 length 15mm 0 6 diameter of tip Electrical Specifications at 23 5 C 73 F 9 F Measurement Range Resolution Accuracy Relative humidity 10 to 9...

Отзывы: