background image

RH210-en-GB_V1.0   12/14 

5

Setup

 

mode

 

Note:

 

The

 

SETUP

 

Mode

 

cannot

 

be

 

accessed

 

if

 

the

 

HOLD

 

or

 

the

 

MIN

MAX

 

function

 

is

 

active.

  

 

1.

 

Open

 

the

 

flap

 

on

 

the

 

meter’s

 

right

 

side

 

to

 

access

 

the

 

recessed

 

SET

 

button.

 

2.

 

Use

 

a

 

paper

 

clip

 

or

 

small

 

screwdriver

 

to

 

press

 

and

 

hold

 

the

 

SET

 

button

 

for

 

at

 

least

 

3

 

seconds

 

until

 

the

 

meter

 

beeps

 

twice.

 

3.

 

The

 

‘Code

 

1000’

 

prompt

 

should

 

appear

 

on

 

the

 

display.

 

Proceed

 

with

 

the

 

steps

 

below:

 

 

Change

 

the

 

Temperature

 

Units

 

of

 

Measure

 

(F/C)

 

With

 

‘Code

 

1000’

 

showing

 

on

 

the

 

display

 

(as

 

explained

 

above),

 

follow

 

the

 

steps

 

below:

 

1.

 

Press

 

REC

 

and

 

the

 

lower

 

display

 

line

 

will

 

show

 

two

 

units

 

of

 

measure

 

icons.

 

The

 

smaller

 

digits

 

indicate

 

the

 

unit

 

of

 

measure

 

that

 

will

 

be

 

adopted

 

when

 

these

 

programming

 

steps

 

are

 

complete.

 

2.

 

To

 

select

 

F,

 

press

 

the

 

Function

 

button

 

so

 

that

 

the

 

number

 

1

 

appears

 

and

 

then

 

press

 

REC.

 

3.

 

To

 

select

 

C,

 

press

 

the

 

Function

 

button

 

so

 

that

 

the

 

number

 

0

 

appears

 

and

 

then

 

press

 

REC.

 

4.

 

Press

 

the

 

HOLD

 

button

 

to

 

save

 

the

 

setting

 

and

 

return

 

to

 

the

 

normal

 

operating

 

mode.

 

The

 

display

 

should

 

now

 

be

 

indicating

 

the

 

programmed

 

unit

 

of

 

measure.

  

 

Enable

Disable

 

the

 

Auto

Power

 

OFF

 

utility

 

With

 

‘Code

 

1000’

 

showing

 

on

 

the

 

display

 

(as

 

explained

 

above),

 

follow

 

the

 

steps

 

below:

 

1.

 

Press

 

the

 

REC

 

button

 

and

 

then

 

press

 

the

 

SET

 

button

 

(briefly)

 

to

 

access

 

the

 

Auto

Off

 

mode.

 

2.

 

To

 

enable

 

the

 

Auto

OFF

 

mode,

 

press

 

the

 

Function

 

button

 

to

 

indicate

 

a

 

1

 

on

 

the

 

display,

 

and

 

then

 

press

 

the

 

REC

 

button.

 

3.

 

To

 

disable

 

the

 

Auto

 

–OFF

 

mode,

 

press

 

the

 

Function

 

button

 

to

 

indicate

 

a

 

0

 

on

 

the

 

display,

 

and

 

then

 

press

 

the

 

REC

 

button.

 

4.

 

Press

 

the

 

HOLD

 

button

 

to

 

save

 

the

 

setting

 

and

 

return

 

to

 

the

 

normal

 

operating

 

mode.

 

  

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание RH210

Страница 1: ...User Guide Hygro Thermometer Model RH210 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...for the latest version of this User Guide Features Air Temperature Relative Humidity and Dew point measurements Detachable probe for ease of use in a variety of measurement environments Fast humidity...

Страница 3: ...at least 2 seconds to switch the meter OFF When powering ON the meter performs a self test whereby the LCD display counts down to zero before stabilizing at the normal operation screen If the meter do...

Страница 4: ...display icon will switch OFF MIN MAX Recording When selected the Data Recording function records the MIN lowest and MAX highest readings 1 Press the REC button once to start recording MIN and MAX rea...

Страница 5: ...press the Function button so that the number 1 appears and then press REC 3 To select C press the Function button so that the number 0 appears and then press REC 4 Press the HOLD button to save the se...

Страница 6: ...apping the battery terminals onto the wired connectors observing correct polarity and inserting the battery into the compartment 6 Install the battery chamber into the meter housing and secure with th...

Страница 7: ...nsions Meter 135 x 60 x 33mm 5 3 x 2 4 x1 3 Probe 197mm 7 8 length 15mm 0 6 diameter of tip Electrical Specifications at 23 5 C 73 F 9 F Measurement Range Resolution Accuracy Relative humidity 10 to 9...

Отзывы: