background image

 

1

TMST-2B-ZBS Thermostat 

 

Introduction 

TMST-2B-ZBS is a battery powered ZigBee Thermostat. It is designed to be incorporated into household heating and 
cooling system for home environment control. The Thermostat can be operated manually using the LCD screen and 
buttons, or accessed remotely via ZigBee network. It feature Cooling, Heating, Auto modes with temperature set point and 
automatic schedule for you to control your home environment easily. 
The Thermostat utilizes ZigBee technology for wireless signal transmission. ZigBee is a wireless communication protocol 
that is reliable and has low power consumption and high transmission efficiency. Based on the IEEE802.15.4 standard, 
ZigBee allows a large amount of devices to be included in a network and coordinated for data exchange and signal 
transmission 
The Thermostat serves as an end device in the ZigBee network. It can be included in the ZigBee network to transmit signal 
upon activation, but cannot permit any other ZigBee device to join the network through the Thermostat.   

 

Parts Identification 

1. LCD Display 

The LCD displays the following information: 

 

A.  ZigBee network connectivity icon          will be displayed when the Thermostat 

has joined ZigBee network and is within signal range.

 

B.  The current mode will be displayed when the Up, Down or Mode button is 

pressed.

 

      Cool: 

 Heat: 

 

Auto:  Interval flash between     and  

 Fan: 

C.  Current time and weekday   

D. Away mode icon      will be displayed when Thermostat is under Away 

mode. 

E.  The temperature can displayed in Celsius or Fahrenheit format.   

2. Low Battery LED Indicator 

The LED flashes when low battery voltage is detected 

3. Test / ZigBee Network Button 

- Press the button once to:   

Send a supervision signal with temperature and set point info. 

- Press and hold for 10 seconds then release to reset the Thermostat.   

4. Down Button 

Press the button to change set point. 

5. Up Button 

Press the button to change set point. 

6. Mode Button 

Press the button to change Thermostat mode. 

7. Away Button 

Press the button to change Thermostat to Away Mode. 

8. Wall Mounting Holes 

Summary of Contents for TMST-2B-ZBS

Page 1: ...nsmit signal upon activation but cannot permit any other ZigBee device to join the network through the Thermostat Parts Identification 1 LCD Display The LCD displays the following information A ZigBee network connectivity icon will be displayed when the Thermostat has joined ZigBee network and is within signal range B The current mode will be displayed when the Up Down or Mode button is pressed Co...

Page 2: ...emperature Setting Cool Heat and Auto Mode Cool Mode Thermostat will activate cooling when temperature rises above Cool setpoint to make sure temperature does not go over the setpoint Heat Mode Thermostat will activate heating when temperature drops below Heat setpoint to make sure temperature does not go below the setpoint Auto Mode Set both Heat and Cool setpoints for auto mode Thermostat will c...

Page 3: ... Gas Electric HVAC Type According to the HVAC system in the home environment select the HVAC type in Thermostat setting Type 1 General Gas Electric HVAC system Type 2 HVAC system with Reversing Valve which operates during Cooling Heat Pump O Type 3 HVAC system with Reversing Valve which operates during Heating Heat Pump B Remote Control After the Thermostat joins a ZigBee network you can control t...

Page 4: ...ar on LCD display 4 After joining the ZigBee network the Thermostat will be registered in the security system in the network automatically Please check the security system control panel or CIE Control and Indicating Equipment to confirm if joining and registration is successful 5 After joining the ZigBee network if the Thermostat loses connection to current ZigBee network the ZigBee connection ico...

Page 5: ...iption Character String 0 32 bytes Read Write O 0x0011 PhysicalEnvironment 8 bit 0x00 0xff Read Write 0x00 O 0x0012 DeviceEnabled Boolean 0x00 0x01 Read Write 0x01 M Attribute of Power Configure Cluster Information Identifier Name Type Range Access Default Mandatory Optional 0x0035 BatteryAlarmMask map8 0b0000 000x Read Write 0b0000 0000 O Attribute of Identify Cluster Information Identifier Name ...

Page 6: ...te 0x04 M 0x0020 StartOfWeek 8 bit Enumeration 0x00 0x06 Read O 0x0021 NumberOfWeeklyTransitions uint8 0x00 0xff Read N A O 0x0022 NumberOfDailyTransitions uint8 0x00 0xff Read N A O 0x0023 TemperatureSetpointHold 8 bit Enumeration 0x00 0x01 Read Write 0x00 O 0x0024 TemperatureSetpointHoldDuration uint16 0xffff 0x05a0 Read Write 0xffff O 0x0025 ThermostatProgrammingOperation Mode map8 0b00xx xxxx ...