TM

 Universal Programmable Room Thermostat (Wired)

(7 day, 5/2 day and 24 hour programme options)

Thank you for purchasing this product. If installing for someone else, please ensure that the 
instructions are handed to the householder.

Please read this manual prior to installation or use.

Always isolate the AC MAINS supply before removing the unit from the back plate.

Do not mix old and new batteries. Do not use rechargeable batteries.

Please leave these instructions with the end user where they should be kept in a safe place for future 
reference

 

Installation

The ideal position to locate the TPST501 Programmable Room Thermostat is about 1.5m above 
floor level, in a location where the thermostat is accessible, reasonably lit and free from extremes of 
temperature and draughts. Do not mount the thermostat on an outside wall, above a radiator or in a 
location where it may be subjected to direct sunlight.

The electrical connections to the TPST501 are made to the standard backplate supplied. 
This simplifies installation, as no connections are made to the controller itself. Connection details are 
shown below – no Earth connection is required for the correct and safe operation of the TPST501, 
but a parking terminal is provided to connect an Earth wire if one is present.

Backplate Connections 

Terminal Name

Function

1:COM

Switch common terminal 

2:NO

Normally open (Volt-Free Contact)

3:NC

Normally closed (Volt-Free Contact)

 

After installing the backplate in a suitable location, wiring connections can be made as shown above. 
The following criteria apply to the installation:
 

• The loading power supply should be 230V AC and fused at 5 amps

 

•  Optimum cable size for installation is 1.5mm

2

, wiring colours should be in accordance with the 

current requirements of the IEE Wiring Regulations

 

• Cable entry should be from the rear of the backplate

 

•  All wiring connections should be securely made, and be firmly gripped between the square 

brass washers on each terminal

Summary of Contents for TPST501

Page 1: ...ion where it may be subjected to direct sunlight The electrical connections to the TPST501 are made to the standard backplate supplied This simplifies installation as no connections are made to the controller itself Connection details are shown below no Earth connection is required for the correct and safe operation of the TPST501 but a parking terminal is provided to connect an Earth wire if one ...

Page 2: ...ST501 onto the backplate without the mains supply to the system being isolated Jumper Settings Changes to the jumper settings should only be made by the Engineer carrying out the installation or other qualified person Jumpers Description Span 3x1 pins jumper for 0 5 C or 1 0 C factory default setting selection It is used to define the system to run at 0 5 C or 1 0 C difference to the set temperatu...

Page 3: ...nnel is turned on for heating 6 Low batt indicator Indicates battery replacement is required 7 Auto Comf Econ Off mode indicator Indicates current mode Auto Comfort Economy Off 8 Set icon Indicates unit in setting mode 9 Program icon Indicates unit in programming mode Both SET and PROG are sown at the same time as SET PROG 10 Snowflake icon Indicates when unit is in OFF mode Initial Power Up After...

Page 4: ...C 2 Time 08 00 Time 10 00 Temp 18 C Temp 21 C 3 Time 12 00 Time 12 00 Temp 21 C Temp 21 C 4 Time 14 00 Time 14 00 Temp 18 C Temp 21 C 5 Time 18 00 Time 18 00 Temp 21 C Temp 21 C 6 Time 22 30 Time 23 00 Temp 16 C Temp 16 C Day Time Setting To set the day press D repeatedly to step through Press and hold the key 2 seconds the Day of the Week will change continuously To set the hour press H repeatedl...

Page 5: ...OMF Mode this setting will be remembered Anytime during the COMF mode press it will go back to the AUTO automatic mode Symbol on the LCD will be off icon will be displayed 2 ECON mode Press anytime to change into ECON mode will be displayed on the LCD Change the setting default 16 C the same as in COMF mode Anytime during the ECON mode press to return to AUTO automatic mode 3 AUTO mode Automatic m...

Page 6: ...am 2 and the Hour will flash for 10 seconds to allow you to set repeat steps 3 to 5 above 7 After Program 6 is set the next Day will flash as in step 1 8 Repeat step 1 to 6 to set the rest days Note During steps 1 8 above only or Select and Set have functionality During steps 1 8 above if there is no key press within 10 seconds the unit will store the current setting and return to AUTO mode Chrono...

Page 7: ...ample New Program 1 Time 06 30am Setpoint Temp 21 C 2 Time 7 00am Setpoint Temp 18 C 3 Time 7 00am Setpoint Temp 23 C 4 Time 7 00am Setpoint Temp 21 C 5 Time 7 00am Setpoint Temp 19 C 6 Time 10 30pm Setpoint Temp 16 C Installer Setting Mode There is one setting for installer Offset from 3 0 C to 3 0 C 1 Press and hold ON OFF over 2 seconds the unit is in Offset selection LCD will display OFS and s...

Page 8: ...tery occurs the backlight will not illuminate Battery Cut off Handling When the batteries reach cut off voltage 2 1V the LCD will turn off After battery cut off occurs the thermostat will enter a cut off state until new batteries have been fitted BOSS is a registered trademark of the Travis Perkins Group Registered Office Travis Perkins plc Lodge Way House Lodge Way Harlestone Road Northampton NN5...