background image

Model: TS42S

7 in 1 Talking Infrared Thermometer

Please read this instruction manual carefully

before using your ear thermometer

For a voice recorded version of this manual please visit

www.snotty.com.au/products/thermometers/7in1- talking-thermometer 

User's Manual

Summary of Contents for TS42S

Page 1: ...ared Thermometer Please read this instruction manual carefully before using your ear thermometer For a voice recorded version of this manual please visit www snotty com au products thermometers 7in1 talking thermometer User s Manual ...

Page 2: ...ification and Caution Description of LCD Display Setting Volume C F and Date Time Using the Thermometer Memory Recall and Deletion Battery Installation Trouble shooting Storage and maintenance Technical Specifications Warranty Contact 1 2 3 4 5 9 14 15 16 17 18 18 19 ...

Page 3: ...h more accurate 7 Waterproof Probe Design Waterproof probe enables easy cleaning and usage 8 One second Reading 9 Power Saving Auto Power Off Auto power off after 30 second idling to ensure longer battery life 10 Low battery Indicator 11 Warning indication low battery symbol and Lo Hi symbol indicating out of measuring range or low battery 12 Large LCD Display Easy to read large LCD display 13 Lar...

Page 4: ...ment make sure that both the thermometer and the patient object have been in the specific environment for at least 30 minutes 9 Avoid measuring temperatures within 30 minutes after exercise bath or change of environment 10 To protect the environment dispose of empty batteries at appropriate collection sites according to national or local regulations 11 Do not disassemble the thermometer 12 Please ...

Page 5: ... cover cap Forehead thermometer mode button forehead Ear thermometer mode On button ear LCD Display Sensor tip with lens cover cap removed Memory button Set button Battery compartment lid Speaker LED signal red high temperature alarm green normal ...

Page 6: ...Time Measurement mode Ear Measurement mode Object Battery warning symbol Measurement display storage space number Memory symbol and Measurement in progress symbol Unit of measurement C Unit of measurement F Speaker symbol Forehead icon ...

Page 7: ...he Year Save the setting and Confirm the entry 3 Date Time Change the Month Save the setting and Confirm the entry Month Change the Date Save the setting and Confirm the entry Date Change the Hour Save the setting and Confirm the entry Hour Change the Min Save the setting and Confirm the entry Min Save the setting 4 End setting loop turn off the unit 5 Setting Volume C F and Date Time ...

Page 8: ...e and time 1 Press the SET button for 5 second to switch the thermometer on The device performs a brief self test all elements of the display are shown for approx 1 second Following a successful self test the device emits two short beeps In Standby mode the date and time are shown and is displayed 2 Turn the device on and the speaker symbol shows whether the Volume function is on or off Press the ...

Page 9: ...7 Setting Volume C F and Date Time Changing from Fahrenheit to Celsius 1 Press the SET button to turn the C F function on and off 2 Press the MEM button to confirm entry ...

Page 10: ...t off 5 After this process the thermometer shows the word OFF in the display and switches off automatically Change the Year Save the setting and Confirm the entry Date Time Change the Month Save the setting and Confirm the entry Month Change the Date Save the setting and Confirm the entry Date Change the Hour Save the setting and Confirm the entry Hour Change the Min Save the setting and Confirm t...

Page 11: ...rrow so the temperature of the eardrum often cannot be recorded and the result displayed is often too low The measurement must not be taken in an ear affected by inflammatory diseases e g discharging pus or secretion after possible ear injuries e g eardrum damage or in the healing period after operative procedures In all of these cases please consult your health professional Use of the thermometer...

Page 12: ...that the sensor tip and also the ear canal are clean As the ear canal is slightly curved you have to pull the ear slightly up and backwards before inserting the sensor tip This is important so that the sensor tip can be pointed directly at the eardrum 4 Insert the sensor tip carefully and press the EAR button for 1 second 5 Release the EAR button The end of the measuring time is signaled with a sh...

Page 13: ...ress the HEAD button for 1 second to switch the thermometer on Following a successful self test the device emits two short beeps 3 Place the measuring head with the forehead cover cap fitted on the temples hold down the HEAD button and move the thermometer smoothly over the forehead to the other temple 4 Then release the HEAD button The end of the measuring time is signaled with a short beep and t...

Page 14: ...r immerse in liquids maintaining a distance of 3 cm 4 Release the EAR button or the HEAD button The end of the measuring time is signaled with a short beep and the measured value appears on the display and is spoken 5 Please note that the displayed temperature is the measured and not the adapted surface temperature It is not the same as the forehead ear temperature 6 To switch back to the Ear Fore...

Page 15: ... pronounce the temperature 2 38 C The reading show on LCD meanwhile the backlight and alert light red will light for 3 sec and then the voice will pronounce the temperature When talking on The Voice Sentence Ear your body temperature is 36 5 C Forehead your body temperature is 36 5 C Object the object temperature is 36 5 C When Talking OFF The light indicator shows only for 3 seconds Red Fever o 3...

Page 16: ...sician or trained healthcare professional 1 Press the MEM button The first reading displayed is the average of all measurements stored in memory 2 Continue to press the MEM button to view the next previously stored measurement Note The memory bank can store up to 30 readings When the number of readings exceeds 30 the oldest data will be replaced with the new record ...

Page 17: ...es of the same type make and capacity Always replace both batteries at the same time Do not use rechargeable batteries Please use batteries free from heavy metals 1 Loosen the screw on the battery compartment lid and pull the lid off downwards 2 Remove the used batteries and insert two new AAA batteries in the direction indicated 3 Place the battery compartment lid back on and screw it closed Disp...

Page 18: ...erate the thermometer only between the specified temperature ranges If necessary clean the sensor tip In the event of a repeated error message contact your retailer or Customer Services Solution The temperature measured is lower than 1 Ear Forehead thermometer mode 10 C 50 0 F 2 Object temperature mode 0 C 32 0 F The operating temperature is not in the range from 16 C 35 C 60 8 F 95 F Operate the ...

Page 19: ...asurement Use a soft dry cloth to clean thermometer body Never use abrasive cleaning agents thinners or benzene for cleaning Do not scratch the surface of the probe lens or the display Do not expose the thermometer to extreme temperatures humidity direct sunlight or shock Store at room temperature ...

Page 20: ... with relative humidity up to 85 non condensing Storage Transportation environment o o o o 25 C 55 C 13 F 131 F with relative humidity up to 85 non condensing o o Display resolution 0 1 C or F Power supply 2 X 1 5V AAA size alkaline batteries Weight 65g with batteries Dimensions 134 3mm 42 4mm 47 6mm L W H Warranty Full 12 months warranty from date of purchase Please save your receipt as proof of ...

Page 21: ...19 ...

Page 22: ......

Page 23: ......

Page 24: ...REP Wellkang Ltd 29 Harley St W1G 9QR LONDON U K Manufactured for Perpetus Pty Ltd Australia ABN 49 142811 069 Made in China SNOTTY P O Box 111 Labrador Qld 4215 Australia web www snotty com au email info snotty com au ...

Reviews: