background image

2                                     382860       Ver. 1.5    2/01

 

2. SPECIFICATIONS 

2.1 General Specifications 

Display 

One Main and three Sub 3-3/4-digit (3999 count) LCDs plus 40-

segment bargraph

 

Max. Input 

Current 

DC/AC : 20A

 

Operating 

Conditions 

0 to 104

o

F (0 to 40

°

C), relative humidity: <75%, not wetting 

 

Storage 

Conditions 

0 to 122

o

F (-10 to 50

°

C), relative humidity: <76%, not wetting

 

Power 

9V Battery: NEDA 1604 9 V or 6F22 

 

Dimensions 

7.36x3.3x1.34” (187x84x34mm)

 

Weight 

9.8oz (305g)

 

 

2.2 Range Specifications 

NOTES:

 Accuracies are % of reading and specified at 23

o

C with RH <75% 

for a period of 1 year after production. Warm-up time is 1 minute. 

    Mode 

Measuring Range 

Accuracy 

Resolution 

400 mV 

100 

µ

4 V 

1 mV 

40 V 

10 mV 

400 V 

± (0.3% + 1dgt) 

100 mV 

DC Voltage 

1000 V 

± (0.5% + 1dgt) 

1 V 

400 

µ

0.1

µ

4mA 

± (1.0% + 1dgt) 

µ

40mA 

10 

µ

400mA 

± (0.8% + 1dgt) 

100

µ

4A 

1mA 

DC Current 

20A 

± (1.5% + 5dgt) 

10mA 

 

                     Accuracy 

    Mode 

Measuring Range 

40Hz-1KHz 

1KHz–10KHz 

Resolution 

400 mV 

0.1mV 

4 V 

1mV 

40 V 

10mV 

400 V(<200V) 

± (0.8%+3dgts)  ± (2.5%+5dgts) 

100mV 

400V(<400V) 

100mV 

AC Voltage 

750 V 

± (1.0%+3dgts) 

N/A 

1V 

400 

µ

0.1

µ

4mA 

1

µ

40mA 

10

µ

400mA 

± (2.5%+5dgts) 

100

µ

4A 

± (1.5%+3dgts) 

1mA 

AC Current 

20A 

± (2.0%+5dgts) 

N/A 

10mA 

 

 

 

Содержание 382860

Страница 1: ...the correct measuring range to achieve best accuracy REL Relative function allows the operator to measure a value with respect to a preset reference value CMP Comparator function allows a comparative measurement to be made the upper lower limits can be defined MEM Memory and RCL Recall functions permit 10 measurements to be stored in memory for later recall AUTO POWER OFF extends the life of the b...

Страница 2: ...ons NOTES Accuracies are of reading and specified at 23o C with RH 75 for a period of 1 year after production Warm up time is 1 minute Mode Measuring Range Accuracy Resolution 400 mV 100 µV 4 V 1 mV 40 V 10 mV 400 V 0 3 1dgt 100 mV DC Voltage 1000 V 0 5 1dgt 1 V 400 µA 0 1µA 4mA 1 0 1dgt 1 µA 40mA 10 µA 400mA 0 8 1dgt 100µA 4A 1mA DC Current 20A 1 5 5dgt 10mA Accuracy Mode Measuring Range 40Hz 1KH...

Страница 3: ...0 Ohm Audible tone approx 40 Ohm Mode Measuring Range Accuracy Power Measurements AC Current AC Voltage True Power True Power Phase angle cosine To 16 A 91 to 120V To 100 W To 4000 W 90 to 90 degrees 2 5dgts 3 3dgts 5 10dgts 2 5dgts Power Factor 00 00 to 1 00 2 3 Overload Protection 400mA AC DC in the mA range Resistance Measurement 40 Mohm overload Protection 250 V DC AC rms Frequency Measurement...

Страница 4: ...ned voltage carrying components may be accessible Terminals can also carry voltage If it is necessary to open the unit for adjustment maintenance repairing or exchange of parts or modules the measuring unit has to be removed from all voltage sources Capacitors can still carry voltage even if the unit has been removed from all voltage sources Please make sure to use new fuses of the proper rating D...

Страница 5: ...t types The supplied test leads are rated for a maximum of 1200V The maximum rating of the multimeter is 1000 VDC max or 750 VAC rms Use special caution when working with voltage above 25 V AC and above 35 V DC SAFETY SYMBOLS This symbol adjacent to another symbol terminal or operating device indicates that the operator must refer to an explanation in the Operating Instructions to avoid personal i...

Страница 6: ...ity check modes UP DOWN Keys Used to 1 Enter reference values in the REL or CMP modes 2 Address stored values in the MEM and RCL modes 3 Manually set the measurement range in the R H function mode 4 Scroll through advanced Functions list UP forward DOWN backward BACKLIGHT ADJUST Key circular blue colored button Press this key to deepen the LCD backlight effect The backlight extinguishes after a 15...

Страница 7: ...ing frequency measurement To return from this function mode press the SET RESET key Auto Hold A H In this function the meter will automatically record the MIN MAX AVG readings taken since this mode was accessed These values are continuously updated To access A H press the FUNCTION key three times Then press the SET RESET key once Use the UP and DOWN keys to select the decimal location for the MIN ...

Страница 8: ...sub display the 2nd recalled value ref No 1 appears on the center sub display and the 3rd recalled value ref No 2 appears on the right side sub display and so on for the remaining locations CMP Comparison Comparison mode allows readings to be compared to user programmable High Low setpoints Press the FUNCTION key and then the DOWN key Press the SET RESET key once and the word LOW should begin flas...

Страница 9: ...c and read the current on the LCD During AC current measurements the middle sub display will show the frequency of the measurement and the main display indicates the current measurement 5 During DC current measurements the left most sub display is updated one second later than the main LCD The middle sub display two seconds later and the right sub LCD three seconds later Attention Never measure cu...

Страница 10: ... or 0 7 V Silicon if the diode is GOOD 4 Reverse the probe tips Red to the cathode and Black to the anode to check the diode s reverse status 5 If OL overload is displayed the diode is open or measures above 2 0 V If a value between 0 V and approx 2 0 is displayed then a good forward voltage drop exists 6 During diode tests the center sub display indicates GOOD if the diode is o k If the diode is ...

Страница 11: ...isplay 2 seconds later and the right 3 seconds later Important Transistor measurement notes Observe the sequence of connections E B C for the transistor Some Darlingtons or special power transistors contain internal base to emitter resistances that could cause erroneous measuring results The hFE measuring value is not an absolute measurement It only indicates if the transistor is operating or not ...

Страница 12: ...e right Always connect the correct contacts for all plug connections The labeling on the Power Adaptor matches the meter s labeled input terminals for convenience 3 Connect the appliance load under test not powered to the socket of the Power Adaptor 4 Power the load under test by inserting the three prong plug into a 117VAC outlet Readings can now be observed on the LCDS 5 The maximum AC current t...

Страница 13: ...per Hour is programmed 3 Press the SET RESET key to begin editing the left most digit will flash Enter the desired value via the UP DOWN keys While programming to move to the next digit for editing use the SET RESET key Digits are selected and ready for editing when they are flashing 4 Press the SET RESET key until the digits cease flashing when finished editing the cost per hour value and then me...

Страница 14: ... numbers 0 010 KHz 10Hz reference no 0 0 050 KHz 50Hz reference no 1 0 060 KHz 60Hz reference no 2 0 100 KHz 100Hz reference no 3 0 400 KHz 400Hz reference no 4 1 010 KHz 1010Hz reference no 5 2 021KHz 2021Hz reference no 6 4 042KHz 4042Hz reference no 7 8 084KHz 8084Hz reference no 8 10 24kHZ 10240Hz reference no 9 Attention Never short the output of the signal generator The output terminal and t...

Страница 15: ...SCOPE VIEW icon Follow the on screen help for specific operation instruction Also refer to the README file in the diskette s SCOPE subdirectory for operation hints 10 MAINTENANCE 10 1 Fuse Replacement Remove power to the meter and removal all connected cables and probes Use a suitable Phillips screwdriver to carefully open the case Remove the defective fuse s and replace it with a new one of the s...

Страница 16: ... 890 7440 for authorization A Return Authorization RA number must be issued before any product is returned to Extech Thesenderis responsible for shipping charges freight insurance and proper packaging to prevent damage in transit This warranty does not apply to defects resulting from action of the user such as misuse improper wiring operation outside of specification improper maintenance or repair...

Отзывы: