3 382860 Ver. 1.5 2/01
Mode
Measuring
Range
Accuracy
Resolution
4kHz
1Hz
40kHz
10Hz
400kHz
100Hz
4MHz
1kHz
Frequency
(Sensitivity:>300mVrms)
40MHz
± (0.1% + 2dgts)
10kHz
Temperature
-40
°
C to 200
°
C ± (3%+5dgts)
+200
°
C to 1200
°
C ± (3%+2dgts)
1
°
C
Mode
Range
Accuracy
Resolution
400
Ω
0.1
Ω
4k
Ω
1Ω
40k
Ω
10
Ω
400k
Ω
100
Ω
4M
Ω
± (0.5% + 1dgts)
1k
Ω
Resistance
40M
Ω
± (1% + 2dgts)
10k
Ω
4nF
1pF
40nF
10pF
400nF
100pF
4uF
1nF
40uF
10nF
Capacitance
400uF
±2.0 (rdg + 2digits)
100nF
Diode Test
Range 0 to 2000mV, Test current 1.5mA
max. at 1 k ohm, Forward Voltage max. 2.0V
1mV
Continuity Check
400 Ohm; Audible tone < approx. 40 Ohm
Mode
Measuring Range
Accuracy
Power Measurements
AC Current
AC Voltage
True Power
True Power
Phase angle (cosine)
To 16 A
91 to 120V
To 100 W
To 4000 W
- 90 to 90 degrees
+/-(2%+5dgts)
+/-(3%+3dgts)
+/-(5%+10dgts)
+/-(2%+5dgts)
Power Factor
00.00 to 1.00
2.3 Overload Protection
•
400mA AC/DC in the mA -range
•
Resistance Measurement: 40 Mohm overload; Protection : 250 V DC/AC rms
•
Frequency Measurement : 40MHz with max 750V DC/AC rms input voltage
•
Diode Test/Continuity Test : overload protection : 250 VDC/VAC rms
•
Logic Test : max. 39.99 VDC overload protection 250 VDC/VAC rms
Attention: Transistor, capacitance and temperature measurements are not
overload protected. Exceeding the max. input limits can be hazardous to
the user and can damage the meter.