Curtiss-Wright | GSM Series Rev. U PN29959 3/28/17
5
WARNING: Attempting to connect the power cable to the
motor feedback connector may cause damage to the
connector. Verify that pin patterns match before attempting to
connect cables to actuator.
Never attempt to connect or disconnect the actuator with power
applied. Dangerous voltages are present. Damage to equipment and
injury to personnel can result. Many amplifiers have voltage present
for a considerable time period after incoming power is removed.
Take care to insure that the amplifier has discharged all power.
2.2 Typical System Wiring
Please refer to www.exlar.com for information on connectors and
wiring.
2.3 Feedback Information
GSM Series actuators incorporate a quadrature incremental encoder
with commutation signals as the primary rotary feedback device. The
alignment of this feedback device is dictated by the amplifier that the end
user chooses for operating the actuator. This amplifier is indicated in the
model number of the GSM Series actuator as a 3 digit code consisting of
2 letters and 1 number.
Typical System Connections