Curtiss-Wright | GSM Series Rev. U PN29959 3/28/17
20
Note: Some actuators are provided with special seals due to chemical
exposure or other special requirements. Contact Exlar if there is a
question about your particular actuator having a standard material main
rod seal gland.
Main Rod Seal Gland Installation/Replacement:
1. Using proper sized gland or spanner wrench, remove existing
seal from actuator face plate, and slide off the actuator rod. This
will require the removal of any rod attachments. One source for
gland wrenches is Martin Fluid Power,
https://www.mfpseals.com/
Exlar
Actuator
Model
Martin Fluid
Power Part No.
Size
(in)
Description
GSM20-30
PH-0695900000
1/2, 5/8
Rod Gland
Wrench
GSM40
PH-0695910000
1
Rod Gland
Wrench
Standard Main
Rod Seal Gland
Part Numbers
Install Torque
GSM20
18929
100 lb-in (11.29 N-m)
GSM30
19020
200 lb-in (22.58 N-m)
GSM40
19021
360 lb-in (40.67 N-m)