Design and function
Interfaces
64
099-000141-EW501
12.01.2016
5.21.4 Connecting the WELDQAS welding data monitoring and documentation system
Network-compatible welding data monitoring and documentation system for digital power sources.
Figure 5-26
Item Symbol Description
0
1
7-pole connection socket (digital)
For connecting digital accessory components
2
Windows PC
3
WELDQAS welding data monitoring and documentation system
4
7-pole connection cable
Connection between switching cabinet and power source
5
Integration option of WELDQAS into existing network systems via network
cables
6
Connection cable included as standard with WELDQAS