Rectifying faults
Display machine control software version
86
099-000141-EW501
12.01.2016
7.5
Display machine control software version
The query of the software versions only serves to inform the authorised service staff. It is
available in the machine configuration menu.
ENTER
+
EXIT
NAVIGATION
Figure 7-2
Display Setting/selection
Exit the menu
Exit
Service menu
Any changes to the service menu should be agreed with the authorised service
personnel.
Software version query (example)
07=
System bus ID
03A0= Version
number
System bus ID and version number are separated by a dot.
7.6
General operating problems
7.6.1
Interface for automated welding
WARNING
No function of the external interrupt equipment (emergency stop switch)!
If the emergency stop circuit has been set up using an external interrupt equipment
connected to the interface for automated welding, the machine must be configured for
this setup. If this is not observed, the power source will ignore the external interrupt
equipment and will not shut down!
• Remove jumper 1 on the T320/1, M320/1 or M321 PCB!