Commissioning
Workpiece lead, general
98
Item No.: 099-004833-EWM01
6.6.1
List of coolants
The following coolants may be used (for item nos., please see the Accessories chapter):
Coolant Temperature
range
KF 23E (Standard)
-10°C to +40°C
KF 37E
-20°C to +10°C
DKF 23E (for plasma machines)
0°C to +40°C
Observe the safety data sheets.
Coolant must be disposed of in accordance with official regulations
(German waste code number: 70104)!
Coolant must not be disposed of together with household waste.
Coolant must not be discharged into the sewerage system.
Recommended cleaning agent: water, if necessary with cleaning agent added.
6.7
Workpiece lead, general
Remove paint, rust and dirt from clamping and welding areas with a wire brush. The workpiece
clamp must be mounted near the welding point and must be fixed in such a way that it cannot
come loose of its own accord.
Structural parts, pipes, rails etc. may not be used as return leads for the welding current unless
they are part of the actual workpiece.
Correct current connection must be ensured when using welding benches and appliances.