Functional characteristics
MIG/MAG welding
Item No.: 099-004833-EWM01
61
5.2.8
Main program A mode
Different welding tasks or positions on a workpiece demand various welding performances (operating
points) or welding programs. The following parameters are stored in each of the up to 16 programs:
• Operating
mode
• Welding
type
• Superpulses
(ON/OFF)
• Wire feed speed (DV2)
• Voltage correction (U2)
• Dynamics
(DYN2)
P
START
, P
B
, and P
END
are factory set as “relative programs”, i.e. they are dependent on a percentage
of the WF value of main program P
A
(switching between relative and absolute wire feed values,
see chapter “WF Speed Switching (absolute / relative)”.
The user can use the following equipment, controls and accessory components to change the main
program welding parameters.
Program
switching
Program
Operating
mode
Welding typ
e
Superpulse
Wire spe
e
d
Voltage
corre
ction
Dyn
a
mics
P0 No
M3.10 or M3.11
Welding machine control
No
P1 to 15
No Yes
Yes
P0 Yes
1)
Yes
2)
M3.30
Wire feed control
Yes
5)
P1 to 15
Yes
No
P0 Yes
2)
Yes
1)
Yes
1)
Yes
1)
M3.00
Wire feed control
Yes
5)
P1 to 15
No
No
No
P0 Yes
1)
Yes
3)
M3.70
Wire feed control
Yes
P1 to 15
Yes
Yes
P0 Yes
Yes
3)
R40
Remote control
Yes
4)
P1 to 15
No
Yes
No
P0 Yes
No
PC300.Net
Software
No
P1 to 15
Yes
1) Setting via rotary dial
2) Setting via changeover switch
3) Internal memory
4) Powercontrol torch not connected
5) Powercontrol torch connected