Functional characteristics
MIG/MAG welding
Item No.: 099-004833-EWM01
41
5.2.5
MIG/MAG functional sequences / operating modes
The following applies during the wire creep phase:
If there is no welding current flowing after 5 seconds (factory setting), the ignition process
is cancelled (ignition error).
The following applies during the welding phase:
If the arc is broken during the welding process and is not re-ignited within 5 seconds
(factory setting), there is an automatic cut-out.
There are optimum pre-sets for welding parameters such as gas pre-flow and free-burn, etc.
for numerous applications (although these can also be changed if required).
5.2.5.1
Explanation of signs and functions
Symbol Meaning
Press torch trigger
Release torch trigger
Tap torch trigger (press briefly and release)
Shielding gas flowing
I
Welding output
Wire electrode is being conveyed
Wire creep
Wire burn-back
Gas pre-flows
Gas post-flows
Non-latched
Special, non-latched
Latched
Special, latched
t
Time
PSTART Ignition program
PA
Main program
PB
Reduced main program
PEND
End program
t2
Spot time