22
CA S M -1 0 0
8.2 Maintenance work
8.2.1 Cleaning
To be performed by operator.
NOTICE
Damage due to incorrect cleaning
Therefore:
• Do not use any aggressive cleaning agents. Water used for clean-
ing, including chemical additives, must be pH-neutral.
• Liquids must not touch the actuator during retraction or extension.
• Only use the auxiliary materials.
• No steam jets or pressure washers may be used for cleaning.
• Other cleaning agents or cleaning devices may only be utilized
with the manufacturer’s approval.
Clean line actuator:
Clean dirty parts with a damp cloth.
8.2.2 Check sealing function
To be performed by qualified personnel.
Device must be stopped and secured.
1. Check seal for damage (1)
2. Check filter and plug for damage (2)
3. Check gaskets for damage (3)
Check for potential leakage in the actuator. If there is no
damage, you can restart the application.
2
1
3
3
NOTICE
Material damage due to damaged or incorrect sealing
Damaged or incorrect seals cannot guarantee protection
pursuant to IP54S or higher.
Therefore:
• Ask the manufacturer to replace the damaged seals immediately.
8.2.3 Check of visual condition
To be performed by qualified personnel.
1. Separate the device from the energy supply.
2. Check the following structural components for visual ex-
ternal damage:
• Check housings for cracks and gaps (1)
• Check profile for cracks, gaps and broken pieces (2)
• Check push tube for scratches and indentations (3)
2
1
3
3
Notify processor or actuator manufacturer in case of dam-
age. If there is no damage and the processor/manufacturer
has not communicated any concerns, reconnect the device
to the power supply.
8.2.4 Relubrication interval
To be performed by qualified personnel.
The relubrication device is optional. Check if the CASM-100 is
equipped with a relubrication plug on the protection tube (1).
1. Run the the actuator to the relubrication position
(⮑ table 3)
2. Stop and secure the actuator/application
3. Open the plug (1)
4. Relubricate the CASM-100 with the specified type and
amount of lubricant (see table below). Compatibility can-
not be granted if other greases are used.
5. Close the relubrication bore before you restart the system!