23
8.0 M a inten a n c e
WARNING
Risk of injury and material damage!
Only open the relubrication bore when the actuator is stopped
and powered off.
CASM-100 linear actuator relubrication interval
Type
Relubrication position
Relubrication interval
Amount of lubricant
Screw type
CASM-100-BA-…
Nominal stroke:
From mechanical end stop:
40 mm
43 mm
Every 10 Mrev or 100 km 8 cm
3
BS 32x10
CASM-100-BB-…
Nominal stroke:
From mechanical end stop:
15,5 mm
18,5 mm
Every 5 Mrev or 50 km
17 cm
3
BS 40x10
CASM-100-BC-…
Nominal stroke:
From mechanical end stop:
3 mm
6 mm
Every 5 Mrev or 100 km
7 cm
3
BS 40x20
CASM-100-RA-…
Nominal stroke:
From mechanical end stop:
2 mm
5 mm
Every 20 Mrev or 200 km*
* First relubrication after
100 000 revolutions
14 cm
3
RS 30x10
Table 3
NOTE
Type BA, BB and BC: Use only the following grease to relubricate
the linear unit: BERUTOX FH 28 EPK / II
Manufacturer: Bechem (www.bechem.de)
Type RA: Use only the following grease to relubricate the lnear
unit: STABUTHERM GH 461.
Manufacturer: Klueber (www.klueber.com)
8.3 Measures after
maintenance completed
Upon completion of the maintenance work, the following
steps have to be performed prior to restarting the device:
1. Check all screw connections for a tight fit.
2. Ensure that all used tools, materials and other equipment
have been removed from the work area.
3. Clean work area and remove potential spills such as
liquids and processing material.
4. Ensure that all safety measures of the system work
without a problem.
5. Check functions.
6. Document completion of the inspections in the service log.
8.4 Maintenance checks
During each service interval, the following measurement/
check needs to be done:
• BS/RS: excessive wear of the ball screw could lead to a
noise increase and a potential blockage of the drive.
Содержание CASM-100