21
8.0 M a inten a n c e
Personnel
• Daily maintenance work described herein can be per-
formed by the operator.
• Some maintenance tasks should only be performed by
specially trained, qualified personnel employed by the
product owner, or exclusively by personnel of the manu-
facturer; specific reference will be made in each case in
the description of the respective maintenance task.
• Only professional electricia.
8.1 Maintenance plan
Maintenance tasks that are required for optimal and trou-
ble-free operation are described in the sections below.
If increased wear is detected during regular inspections,
shorten the required maintenance intervals according to the
actual indications of wear.
CASM-100 linear actuator maintenance plan
Interval
Maintenance work
To be carried out by
Daily
Check actuator for visible damage (⮑ 8.2.3 Check of visual condition, page 22).
Clean off dust and dirt if necessary (⮑ 8.2.1 Cleaning, page 22).
Operator
Monthly
Check tight fit of the rod and options, correct if necessary. Check connection for tight fit.
Check relubrication interval (⮑ 8.2.4 Relubrication interval, page 22).
Qualified personnel
Annually
Check labels and warning notices for legibility and replace if necessary.
Check sealings for damage (⮑ 8.2.2 Check sealing function, page 22) .
Check relubrication interval (⮑ 8.2.4 Relubrication interval, page 22).
Qualified personnel
Semi-annually
Check options for visible damage
Check relubrication interval (⮑ 8.2.4 Relubrication interval, page 22).
Qualified personnel
NOTICE
If the linear actuator is used outside of the environmental
conditions specified earlier in this manual, check such
components once a month for any changes such as oxidation or
sedimentation.
8.0 Maintenance