IONPURE
®
DC POWER CONTROLLER
– IP-POWER600-G2
IP-POWER600-G2 MAN REV. 11
Page 11 of 28
2.4
Selector Switches
2.4.1
DIP Switch for Current Range Selection
DC output current range is selected via a current range DIP switch, as described in Figure 1.
Figure 1: Current Range Selection DIP Switch
The default current setting is 0-2.5 amps.
Refer to Table 3 in Appendix A
for correct current range settings (from column “Maximum
Required DC Amps”).
2.4.2
Rotary Switch for Selection of Voltage Metering Output Range and Unit ID
Rotary switch SW2 (see Figure 6) has dual functionality:
Switches the analog output range for voltage metering (Vm, see section 2.5.4) between
0-5VDC and 0-6VDC.
Positions 0 to E set the voltage range to 0-5 VDC. This range should be set when using
Ionpure® IP-DSP1-P or IP-DSP8-P display boards.
Position F sets the voltage range to 0-6 VDC. This range should be set when using
Ionpure® IP-DSP1 or IP-DSP8 display boards.
Assigns a unique identification number/letter to the power controller when using an
Ionpure
®
G2 display.