54
01-2019 5505 00
t
EmpEraturE
tEst
This group of functions that may be of use
after having acted on the cooling unit is
intended to check the operation of the cool-
ing unit and the internal temperature probe.
start
tEst
It is intended to start the temperature test.
The operator is required to enter an identi-
fication code (that may be even zero) and
the refrigerated box temperature is detect-
ed and stored every 30 seconds for a 20-
min. normal operation.
Press the Enter key
to display the
test progress and the number of acquisi-
tions made.
The machine is available for the other func-
tions
during the temperature test.
tEmpEraturE
Connect a serial printer with the follow-
ing communication parameters: baud rate
9600, 8 data bits, no parity, 1 stop bit, to the
RS232 serial connector inside the door to
print the temperatures measured during the
test.
To print the stored data, act as follows:
-If you confirm, the request for confirmation
will appear on the screen
-Connect the printer before confirming.
-Press key
to start printing.
stop
tEst
The function is used to stop acquiring the
temperature in the refrigerated box.
Export
oN
upkEy
It exports the temperatures measured dur-
ing the temperature test on an upkey.
STATISTICS
All the machine operation data are stored in
total and relative counters that can be reset
without losing total data.
E
lEctroNic
couNtEr
D
isplay
tHE
ElEctroNic
couNtEr
An electronic counter is intended to store
all the dispensing cycles you have per-
formed since you last reset it in an aggre-
gated manner.
r
EsEt
tHE
ElEctroNic
couNtEr
You can reset the electronic counter.
D
isplay
tHE
ElEctroNic
couNtEr
To enable / disable the display of the to-
tal number of dispensing cycles that have
been made since you last reset the sta-
tistics, while you are powering on the ma-
chine.