Operating Instructions
NPC-8210
- 21 -
close_system
Close system, and input on CLI interface
cli>close_system
Input close_system to check whether “close system”
is finished. If the system is not shut down within 2
minutes, automatic power-off will be executed, and
no response will be given to other command in the 2
minutes of monitoring.
set_ip
Set IP; input set_ip, IP address, network gate address
and subnet mask code
cli>set_ip
192.168.102.254
192.168.105.3 255.255.255.0
After inputting ip, the network is disconnected. Use
new ip address for login.
get_log
Check abnormal temperature log. Input get_log to
check abnormal information, which includes time,
faulty parts and temperature.
get_mac
Check IPMI network card MAC address, and input
get_mac on CLI interface
002246xxxxxxx
get_time
Check IPMI system time, and input get_time on CLI
interface
2013.01.01 12:00
set_time
Set IPMI system time, and input on CLI interface
cli > set_time
2013-1-1 13:00
disconnect
Disconnect telnet link, and input on CLI interface
cli >disconnect
reset_ipmi
Reset IPMI, and input on CLI interface
cli >reset_ipmi