EQT-1616-3G-C-C
EQT 12G/3G/HD Router
Page 15
4.2.1.2. To change the IP address of the components via Serial connection
For the EQT:
1. Connect a DB-9 cable to the DEBUG/SERIAL port on the rear of the router
2. Set connection parameters as follows:
Speed
115200
Data
8-bit
Parity
None
Stop Bits
1 bit
Flow Control None
3. When prompted, log in with login/password combination
customer/customer
4. Once the configuration menu is displayed, select the Network Setup menu
5. Follow the on-screen instructions to set the IP address, subnet mask, gateway, and broadcast
address
6. Make sure to select the option to Save and Exit when changes are complete
7. Wait 30 seconds for changes to be applied
8. Reboot the EQT for changes to take effect
For the Control Panel:
1. Connect a DB-9 cable to the SERIAL port on the rear of the router
2. Set connection parameters as follows:
Speed
115200
Data
8-bit
Parity
None
Stop Bits
1 bit
Flow Control
None
3. Once the configuration menu is displayed, select the Network Setup menu
4. Follow the on-screen instructions to set the IP address, subnet mask, gateway, and broadcast
address
5. Make sure to select the option to Save and Exit when changes are complete
6. Wait 30 seconds for changes to be applied
7. Reboot the EQT for changes to take effect
NOTE: The device must be rebooted in order for network changes to take
effect.
Содержание EQT-1616-3G-C
Страница 2: ...This page left intentionally blank ...
Страница 6: ...EQT 1616 3G C C EQT 12G 3G HD Router Page ii This page left intentionally blank ...
Страница 12: ...EQT 1616 3G C C EQT 12G 3G HD Router Page viii Page left intentionally blank ...
Страница 22: ...EQT 1616 3G C C EQT 12G 3G HD Router Page 10 This page left intentionally blank ...
Страница 36: ...EQT 1616 3G C C EQT 12G 3G HD Router Page 24 This page left intentionally blank ...
Страница 43: ...EQT 1616 3G C C EQT 12G 3G HD Router Page 31 6 3 SYSTEM Figure 6 3 WebEASY System ...
Страница 48: ...EQT 1616 3G C C EQT 12G 3G HD Router Page 36 6 6 SIGNAL STATUS Figure 6 6 WebEASY Signal Status ...
Страница 61: ...EQT 1616 3G C C EQT 12G 3G HD Router Page 49 7 4 CONFIGURATION Figure 7 3 VistaLINK Configuration ...
Страница 64: ...EQT 1616 3G C C EQT 12G 3G HD Router Page 52 7 5 SIGNAL STATUS Figure 7 4 VistaLINK Signal Status ...
Страница 73: ...EQT 1616 3G C C EQT 12G 3G HD Router Page 61 7 11 MANAGE ROUTES Figure 7 10 VistaLINK Manage Routes Part 1 ...
Страница 84: ...EQT 1616 3G C C EQT 12G 3G HD Router Page 72 Figure 8 10 WinSeup Ethernet Port Settings Serial ...
Страница 98: ...EQT 1616 3G C C EQT 12G 3G HD Router Page 86 This page left intentionally blank ...
Страница 102: ...EQT 1616 3G C C EQT 12G 3G HD Router Page 90 End of Document ...